LS-S5700-24TP-PWR-SI

S5700-24TP-PWR-SI

Part Number:   02352369

Description:
20 10/100/1000 Base-T and 4 GE Combo, PoE, Dual Slots of power, Without Power Module
Availability:   In Stock
  units
 


key Feature
  • 24 Ethernet 10/100/1000 ports, 

    4 of which are Combo 10/100/1000 

    or SFP ports

  • AC 110V/220V power

  • PoE+

  • Forwarding performance: 36 Mpps

What's Included
  • LS-S5700-24TP-PWR-SI  1PCS

 
Overview
  • Huawei S5700-24TP-PWR-SI Switch

  • 20 GE POE ports, 4 GE Combo ports

  • One console port, One ETH management port, One USB port

  • POE Switch, support POE+

  • Layer 3 Ethernet Switch

  • Fixed AC 110V/220V power

  • Fixed Configuration Switch

  • Need to purchase additional power W0PSA5000

  • Software: Standard Version

  • Intelligent Stacking(iStack)

  • Support Static routing

  • Packing size: 577*595*130mm

  • Weight: 6.4KG


    Huawei Quidway S5700 series gigabit enterprise switches is designed for high-bandwidth access and Ethernet aggregation. Huawei Quidway S5700 can be used in various campus network scenarios: access switch, aggregation switch, gigabit access switch in Internet data center, or desktop switch to provide 1000 Mbps access for terminals. 


 
Tech Specs
Specification
Fixed portTwenty 10/100/1000Base-T ports and four GE combo ports
Extended slotOne extended slot for a stack card
Forwarding performance36 Mpps
MAC address tableIEEE 802.1d compliance
16 K MAC address entries on the S5700SI
MAC address learning and aging
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
VLAN4K VLANs
Guest VLAN and voice VLAN
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
1:1 and N:1 VLAN Mapping
SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series)
ReliabilityRRPP ring topology and RRPP multi-instance
Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover
SEP
E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series)
STP, RSTP, and MSTP
BPDU protection, root protection, and loop protection
MPLS featuresNot supported
IP routingStatic routing, ECMP
RIPv1, RIPv2 and RIPng
IPv6 featuresNeighbor Discovery (ND)
Path MTU (PMTU)
IPv6 ping, IPv6 tracert, and IPv6 Telnet
ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type
MLD v1/v2 snooping
6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series)
MulticastIGMP v1/v2/v3 snooping and IGMP fast leave
Multicast forwarding in a VLAN and multicast replication between VLANs
Multicast load balancing among member ports of a trunk
Controllable multicast
Port-based multicast traffic statistics
QoS/ACLRate limiting on packets sent and received by an interface
Packet redirection
Port-based traffic policing and two-rate three-color CAR
Eight queues on each port
WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms
Re-marking of the 802.1p priority and DSCP priority
Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID
Rate limiting in each queue and traffic shaping on ports
SecurityUser privilege management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, interface, and VLAN
Port isolation, port security, and sticky MAC
Blackhole MAC address entries
Limit on the number of learned MAC addresses
802.1x authentication and limit on the number of users on an interface
AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC
SSH v2.0
Hypertext Transfer Protocol Secure (HTTPS)
CPU defense
Blacklist and whitelist
OAMSupports
Management and maintenanceVirtual cable test
Stacking (The S5700HI do not support this function)
MAC Forced Forwarding (MFF)
Port mirroring and RSPAN (remote port mirroring)
Remote configuration and maintenance using Telnet
SNMP v1/v2/v3
RMON
Web NMS
HGMP
System logs and alarms of different levels
GVRP
MUX VLAN
DDR memory256 MB
Flash memory32 MB
Mean time between failures (MTBF)S5700-24TP-PWR-SI: 84.3 years
Mean time to repair (MTTR)2 hours
Availability> 0.99999
Surge protection: Service port protectionPoE switch: ±1 kV in common mode
Surge protection: Power supply protectionPoE switch: ±2 kV in differential mode; ±4 kV in common mode
Stack portTwo stack ports available on each stack card
Maximum stack bandwidth (bidirectional)48 Gbit/s
RPSNot supported
PoEThe PWR series support PoE.
Input DC voltage: Rated input voltage range-48 V DC to -60 V DC
Input DC voltage: Maximum voltage range-36 V DC to -72 V DC
Input AC voltage: Rated input voltage range100 V AC to 240 V AC, 50/60 Hz
Input AC voltage: Maximum voltage range90 V AC to 264 V AC, 47 Hz to 63 Hz
Maximum system power consumption (100% throughput, 100% PoE loads, full speed of fans)S5700-24TP-PWR-SI: 455 W (system power consumption: 85 W; PoE: 370 W)
Operating temperature0°C to +50°C
Storage temperature-40°C to +70°C
Noise under normal temperature (27°C, sound power)S5700-24TP-PWR-SI: less than 51 dBA
Relative humidity5% RH to 95% RH, noncondensing
Operating altitudePoE switch: 0 m to 5000 m
EMCCISPR22 Class A
CISPR24
EN55022 Class A
EN50024
ETSI EN 300 386 Class A
CFR 47 FCC Part 15 Class A
ICES 003 Class A
AS/NZS CISPR22 Class A
IEC61000-4-2
ITU-T K 20
ITU-T K 44
Environmental standardsRoHS
REACH
WEEE
SecurityIEC 60950-1
EN 60950-1/A11/A12
UL 60950-1
CSA C22.2 No 60950-1
AS/NZS 60950.1
Laser safetyIEC60825-1
IEC60825-1
EN60825-1
EN60825-2
Dimensions (W x D x H)442.0 mm x 420.0 mm x 43.6 mm
Fully loaded≤ 8.5 kg
Empty loaded≤ 5 kg
 
Q & A

Q: Does S5700-24TP-PWR-SI support stack?

A: Yes, but it is not through the stack card, it is through the GE uplink interface.

V200R001: The last two uplink 1000Base-X optical ports can be used as stack ports.

V200R002 and later versions: The four uplink 1000Base-X optical ports can be used as stack ports.


Q: What is the difference between Huawei 5700 switch and 5300 switch?

A: Huawei S5700 target the enterprise market, S5300 target at telecom market, but most function are the same, the manufacturer did this mostly for marketing reasons as the telecom market most are big customers with better discount.


Q: Can an Electrical Interface of the S5700 Be Connected to an O/E Converter?

A: An optical interface of the S5700 can be connected to an O/E converter.


Q: Does the S5700 Interface Support 100M Optical Modules?

AFixed optical interfaces on the S5700-EI, S5700-SI, S5710-LI, and S5700-HI support 100M optical modules, while interfaces on extended front cards do not support 100M optical modules.

    Combo optical interfaces and 100/1000Base-X optical interfaces on the S5700-LI and S5700S-LI series switches support 100M optical modules.

    The S5710-EI series switches support 100M optical modules only on their combo optical interfaces.

    Combo optical interfaces and 100/1000Base-X optical interfaces on the S5720-EI series switches support 100M optical modules.

    In the S5720-HI series, only the S5720-32C-HI-24S-AC supports 100M optical modules on their 100/1000Base-X optical interfaces.

    The S5720-SI series switches support 100M optical modules only on their combo optical interfaces.


Q: How Do I Know that the S5700's Fan Operates Normally in Intelligent Mode?

A: The fans can work in the intelligent mode or forcible mode.

     In the intelligent mode, the fans start to operate only when the ambient temperature goes higher than a specified value. In V200R003C00 and later versions, you can run the display fan speed-adjust threshold minus command on the switches that use the intelligent heat dissipation mode to view the temperature thresholds for the fans to start and stop running. The set fan speed-adjust threshold minus command can be used to lower these temperature thresholds.  

Intelligent heat dissipation:  

• S5700-24TP-SI-AC 

• S5700-24TP-SI-DC 

• S5700-48TP-SI-AC 

• S5700-48TP-SI-DC


Q: Does the S5700 Support LRM Optical Modules?

A: The S5700SI supports long reach multimode (LRM) optical modules since V100R006C00SPC800. The S5700EI supports LRM optical modules since V100R006C01.

The S5700-LI (10GE optical ports), S5710-C-LI (10GE optical ports), S5700-HI (10GE optical ports), S5710-EI (10GE optical ports), and S5720-EI (only 10GE optical ports on extended interface cards) support LRM optical modules.


Q: Do 10GE Front Subcards of S5700 Switches Support GE/10GE Auto-Sensing?

A: The 10GE front subcards of the S5700EI do not support GE/10G auto-sensing, and 10GE front subcards of the S5700HI and S5700SI support GE/10G auto-sensing.


Q: Can 4*GE and 4*10GE Front Subcards of the S5700EI and S5700SI Switches Be Used Without an Extended Rear Subcard?

A: When a 4*GE or 4*10GE front subcard is used without an extended rear subcard, only two of the four ports on the subcard can be used: 

• 4*GE subcard: Only the first and second ports can be initialized. The ports are displayed as GigabitEthernet */1/1 and GigabitEthernet */1/2 after initialization. 

• 4*10GE subcard: Only the first and third ports can be initialized. The ports are displayed as XGigabitEthernet */1/1 and XGigabitEthernet */1/2 after initialization.


Q: Are the Cards of S5700 Hot Swappable?

A: Interface cards on the S5700 series except for the S5700EI and S5700SI are hot swappable.


Q: Why Only Two Optical Interfaces Are Displayed After a Front Card Is Installed on an S5700?

A: The reason is that no extended rear card is installed on the S5700.

    An S5700-EI or S5700-SI can provide only two optical interfaces for a front card. If a 4-port front card is installed, an ETPB extended rear card must be installed to provide the other two ports. Otherwise, only two optical interfaces are displayed.


Q: Can the Front Card and Stack Card of the S5700C Be Used Simultaneously?

A: When a 2-port front card is installed, the front card and the stack card can be used simultaneously. If a 4-port front card (ES5D000X4S01, ES5D00G4SA01, or ES5D000G4S01) is installed, an ES5D00ETPB00 extended rear card must be installed.


Q: Are Subcards of the S5700SI and S5700EI Support 10GE Ports?

A: The S5700SI and S5700EI switches use front subcards to provide 10GE ports. The ES5D000X2S00 and ES5D000X4S01 front subcards provide 10GE ports on the S5700SI and S5700EI switches. They use SFP+ optical modules.

     The S5700SI and S5700EI switches support the ES5D000X2S00 and ES5D000X4S01 front subcards since V100R005. 

• An ES5D000X2S00 front subcard can be used without a rear subcard or together with a rear subcard supported by the switches. 

• When an ES5D000X4S01 front subcard is used together with an ES5D00ETPB00 extended rear subcard of which the PCB version is VER.C, all the four ports on the ES5D000X4S01 front subcard can be used. If an ES5D000X4S01 front subcard is used without an ES5D00ETPB00 extended rear subcard or used together with a stack rear subcard, only the first and third ports on the front subcard can be used. The two ports are displayed as XGigabitEthernet */1/1 and XGigabitEthernet */1/2 in command lines.


Q: SW5700 Can GE Optical Ports Use 10GE Optical Modules?

A: The four uplink GE optical ports of the S5720-P-SI and S5720S-P-SI series can use 10GE optical modules, but can only be used for stack connections in this case. GE optical ports of other switch models cannot use 10GE optical modules. 100M optical ports cannot use GE or 10GE optical modules.


Q: Can Thunder-link.com provide MIB for Huawei S5700 switch?

A: Yes, you may contact our sales person


Q: Can I get technical support from Thunder-link.com if we purchase S5700-24TP-PWR-SI from you?

A: Yes, Thunder-link.com has experienced technical team on Huawei switches, however, you may need to purchase technical support service from us as by default we only provide one year hardware warranty.


Delivery & Payment
Delivery
 
Thunder-link.com have regular products in stock, and work together with reliable and high efficiency shipment partner, could deliver to our customers worldwide shortly. In normal condition, your cargo would take 3-5 days lead time and inland transportation to your carriers, then takes delivery days as per different delivery method, would be arrived at your destination safely and securely through reliable international carriers. Tracking No. will be provided once delivery out.
 
There are 3 delivery methods as default selection.
· FCA China Mainland.
Free of charge for FCA China Mainland
 
· FCA Hong Kong.
Flat rate 150USD for cargo under 100KG. We can delivery to your appointed address in Hong Kong, like your forwarders address.
Please note:
1, Our warehouses and cargoes are not located in Hong Kong, there are logistic and customs commission charges during China to Hong Kong.
2, If your cargo is small dimension, instead of delivery to you Hong Kong carrier, choosing our DHL service to deliver to your country directly is highly recommended.
 
· CNF.
International shipping methods are by express like DHL/ Fedex/ UPS, DHL is default; or by normal airfreight;

For cargoes under 45kg, DHL is recommended; For cargoes more than 45kg, considering the time-effectiveness, customs clearance convenience, and freight cost, our sales team will provide DHL and normal airfreight cost for your choice.

Please note: 

1, Insurance is not included by default, please tell our sales team if you need a insurance during transportation.

2, DHL is door to door service, if you choose normal airfreight, you should collect the cargo at airport; and if there have no airport at your city, you should also responsible for the inland transportation between airport to your place.
 

Payment

 
Thunder-link.com accepts variety payment methods. We will constantly upgrade our payment system and provide the most convenient method for our client. The Customer may make payment by any one of the following methods, and Wire Transfer is the regular method in Thunder-link.com.
 
Payment Methods:
wire transfer western union alipay paypal jbc American express discover network mastercard visa
 
Paying with Wire Transfer
 hsbc
 
You can do from any your local bank. Usually, we will have your payment within 2 to 3 day.
All fee (payer & payee) generated by the bank wire transfer should be bear by client. Otherwise, the fee will be deducted from the payment we receive.
 
Paying with Paypal
 paypal
 
Thunder-link.com offers an alternative secure payment method via PayPal. PayPal does not insist you open an account, making payment by Credit or Debit card even easier. It's advised you do create an account to enable the benefits of signing up with PayPal, such as buyer protection and faster checkout next time without the need to enter your card details. Our invoicing and back order systems with PayPal work differently from our other payment methods. Our returns system is slightly different, we can only refund you for the items rather than swap them. When paying through PayPal the total order amount will be paid for immediately at checkout when you commit to buy. The items will then be dispatched when we process the order as quickly as we can. If items are out of stock we will aim to dispatch them as soon as possible after they arrive here. The same applies for any back orders that are created due to out of stock items within a larger order. Any canceled orders will be refunded as quickly as possible. Any returns will always be charged back to your original payment method.
 
Paying with Western Union
 western union
 
When you buy some items in Thunder-link.com, you have the option of paying for them at any participating Western Union location. The Western Union charge that applies to Thunder-link.com is based on the total amount of your transaction.
All fee (payer & payee) generated by the bank wire transfer should be paid by client.Otherwise, the fee will be deducted from the payment we receive.

Paying with Alipay

1450749079405356.png

Now Alipay is acceptable at Thunder-link.com, if you have and intend to pay by an Alipay account, please contact with our sales team.

Please send us the T/T payment advice with date and invoice number by using below email or telephone number.
Email to: [email protected]          Call to : +852-3062-3083
 



Warranty
 
All products are vender original products, we provide new equipment for customers, never been used before. Some scratching or copper rust might be seen on the modules, that may caused by carry, inserting in/out from chassis during our in-stock and pre-delivery testing. In normal condition, the scratching and rust are very slightly. When meet with this situation, a picture will send to you first to obtain your confirmation before delivery to you.
 
Once you bought products from us, we will provide the best post sale service for you. After the shipping out, we will continuously track your cargo until it arrives to your country or region. If there is something wrong during the delivery, we will do our utmost to help you.
 
Generally, all products provided by Thunder-link.com, will come with standard vender like 1 year warranty. During the warranty period, Thunder-link.com will replace any defective Equipment, but the reverse logistics should responsible by buyer, the re-shipment should obey the trade terms of order. If it is unable to locate a suitable replacement, Thunder-link.com will repair the Equipment. If it is unable to do either, Thunder-link.com will refund the purchase price to Buyer.
 
This warranty does not apply to any failure of the Equipment as a result of misuse, abuse, accident, neglect or mishandling, lack of proper maintenance, environmental factors, improper installation or configuration, flood, fire or other natural disasters, physical damage, electrical issues such as lightning, power surges or incorrect electrical voltages, or improper modifications.
 
This warranty is only valid for the original purchaser of the Equipment (“Buyer”).
But if products fail during warranty time, please contact your sales representative, or email to
[email protected] to verify your problem and enquire solutions for the failed products. If the problem
still can't be fixed by remote support trouble shooting methods i.e. email or phone support, then return procedure
triggered.
 
See details when you start the return procedure to return policy.
 
If there’s any post sale question please e-mail at [email protected] or contact with your sales representative.
 




 
Reviews

Write a review

Note: HTML is not translated!
    Bad           Good

Downloads

Bestsellers

LS-S5700-24TP-PWR-SI

  • LS-S5700-24TP-PWR-SI
  • LS-S5700-24TP-PWR-SI
  • LS-S5700-24TP-PWR-SI
  • LS-S5700-24TP-PWR-SI
  • LS-S5700-24TP-PWR-SI
  • LS-S5700-24TP-PWR-SI
  • LS-S5700-24TP-PWR-SI
  • LS-S5700-24TP-PWR-SI