Flash Space Exhaustion Caused by a License Defect-20120207-A

Summary: When an OptiX PTN 950 NE is configured with two system control boards (active and standby),

the license modules on the system control boards accumulate the board debugging information. The

accumulated debugging information exhausts the space of the flash memory, leading to a failure to save

the configuration data and back up the NE database.

Product Family: PTN                                                  Product Model: OptiX PTN 950

[Problem Description]

Trigger conditions:

The OptiX PTN 950 NE uses two system control boards which run the V100R002C01SPC100 NE

software.

 

Symptom:

The standby system control board exhausts the flash memory space at a speed two times faster than

the active system control board. Therefore, the fault first occurs on the standby system control board.

During the periodical backup of the NE database, if the flash memory has insufficient free space, the

system control board reports a DBMS_ERROR alarm. And also lead to memory leaks, if the memory

leak reaches the threshold, then reported MEM_OVER alarm.

Incremental files are generated when configuration data is delivered or when dynamic services are

configured.

If the flash space becomes insufficient during the process of generating incremental files, the system

control board may fail to generate these incremental files. When this occurs, the NE is reset.

During an NE upgrade, when the NE detects that the free space on the flash memory is insufficient to

save the new software, the NE upgrade fails.

 

Identification method:

The NE type is OptiX PTN 950 and the NE version is V100R002C01SPC100.

The NE uses two system control boards.

 

[Root Cause]

The license module of the system control board software has a defect in data processing. Due to this

defect, the debugging information about the active and standby system control boards continuously

accumulates, exhausting the space of the flash memory. The debugging information occupies 1 MB

flash space every 20 days for the active system control board but every 10 days for the standby system

control board. (The debugging information has no impact on the device functions and applications.)

 

[Impact and Risk]

The active and standby system control boards run out of the flash space.

When the NE database is being backed up, if the free space on the flash memory becomes insufficient,

the database will fail to be backed up. Then the new configuration cannot persist and may be lost once

the NE is reset. And also lead to memory leaks, if the memory leak reaches the threshold, then reported

alarm.

After running out memory will cause the control board reset.

If the free space on the flash memory becomes insufficient during the process of generating incremental

files, then the files will fail to be generated, causing the NE to be reset.

During an NE upgrade, if the free space is insufficient, the NE will fail to load the new software and as

a result the NE upgrade will fail.

 

[Measures and Solutions]

Recovery measures:

1 When a DBMS_ERROR or MEM_OVER alarm is reported, do as follows:

1.1 Run the following commands to check whether there is an HBUMSG.TXT file on the active and

standby system control boards:

:sftm-show-dir:7,”ofs1/license”

:sftm-show-dir:8,”ofs1/license”

1.2 If there is an HBUMSG.TXT file on the two boards, delete the file by running the following

commands:

:sftm-delete-file:7,”ofs1/license/HBUMSG.TXT”

:sftm-delete-file:8,”ofs1/license/HBUMSG.TXT”

1.3 Manual backup database

:dbms-copy-all:drdb,fdb;

If it is MEM_OVER Soft reset the alarm control board

:cfg-reset-board:$the slot of the alarm control board,soft

 

2 When the system control board reset, do as follows:

For a failure to synchronize data between the active and standby system control boards, run the

following command on the active system control board:

:sm-set-nebusy:0,0,0,0,none

2.1 Run the following commands to check whether there is an HBUMSG.TXT file on the active

and standby system control boards:

:sftm-show-dir:7,”ofs1/license”

:sftm-show-dir:8,”ofs1/license”

2.2 If there is an HBUMSG.TXT file on the two boards, delete the file by running the following

commands:

:sftm-delete-file:7,”ofs1/license/HBUMSG.TXT”

:sftm-delete-file:8,”ofs1/license/HBUMSG.TXT”

 

2.3 If the new configuration data is lost, the relate services may affect, please reconfigure the relate

services.

 

Workarounds:

Use the SmartKit Inspector to periodically perform preventive maintenance inspections (PMIs) of

NEs of the specified version (V100R002C01SPC100).You are advised to perform the PMI every

three months.

On the live network the version of the SmartKit Inspector is V100R006C00. Before performing a

PMI, use the automatic upgrade function to upgrade the tool to the CN-PTN Box=P004 patch

version, the later version Inspector also has the similar item.

 

After installing the CN-PTN Box=P004 patch, load the

R6FP005BP004_PreUpgrading_checking_Template.xml file to the SmartKit Inspector to

perform the PMI.

 

Preventive measures:

Install the V100R002C01SPH102 patch or upgrade the NE to a later version.