For OptiX OSN 1800 V100R003C01SPC200 (5.67.03.23) or an earlier version, services on the

TNF2LQM or TNF2LDGF2 board that uses the service chip of version V110 will be unavailable

after the board is initialized because of a bug. The problem can be resolved by upgrading the

OptiX OSN 1800 to V100R003C01SPC300 (5.67.03.25) or a later version.

[Problem Description]

Trigger conditions:

The problem occurs when the following conditions are present:

The TNF2LQM or TNF2LDGF2 board uses the service chip of version V110.

The NE software version is V100R003C01SPC200 or earlier.

Symptom:

Services are unavailable after the board is powered on and configured with services.

Identification method:

 

Run the following command to query the service chip version on the board:

:woptp:$bid,1,83,1,ff,23,00,04,10,00,2         # “bid” indicates the slot ID of the TNF2LQM or

TNF2LDGF2 board in the hexadecimal format.

The following information may be returned:

Optp cmd : ff23

00 04 10 00 02 87 51 00 11      # “00 11” indicates that the service chip version is 110.

If “00 11” is displayed in the returned information, the board is involved in this warning.

 

[Root Cause]

For OptiX OSN 1800 V100R003C01SPC200 and earlier versions, the TNF2LQM and

TNF2LDGF2 boards that use the service chip of version V110 have a bug in board initialization.

 

[Impact and Risk]

Affected scope: in and out of China

Risk: The services are unavailable.

 

[Measures and Solutions]

Recovery measures:

Upgrade the OptiX OSN 1800 to V100R003C01SPC300 or later and perform a cold reset on

the involved board.

Workarounds:

None

Preventive measures:

See “Recovery measures” as described above.

 