When unable to configure OSN1800 using built in WebLCT TL1 without need U2000 or WebLCT on laptop?

Issue Description

The OSN 1800 can be acess and configured without using U2000 or WebLCT on laptop, instead using the built-in tool , OSN1800 WebLCT for TL1.
Open Internet Explorer, type htp:// ‘ Ne ip address’
Login page appears ”OSN1800 Weblct For TL1”
Problem occur, once input username n password, 4seconds later we were pushed out from the system with error display – Web Services Inhibited

Alarm Information

None

Handling Process

Upon failure to login in , we checked username and password is correct. Checked Internet Explorer setting for ”off” proxy and security settings ”Low”. Checked to make sure NE IP is correct with Navigator. And found out for OSN1800 customized for North America, this feature/tool is disabled.

SO enable it by changing the pin setting on J51 on the SCC board.
Refer to attached PDF for step by step explanation to enable this tool on customized OSN1800 for North America

 

Root Cause

Reason was the OSN1800 was customized for North America. This is determined by the jumper pin on J51 on the SCC board.

Suggestions

This built in tool is important and useful to engineers on-site for commissioning OSN 1800 in case U2000 failure or don’t have U2000/WebLCT .
Sometimes engineer laptop can have problem loading U2000 or slow and with the customer pushing Huawei for fast commissioning, using this tool will be very helpful.

Hope this helps engineers to have better knowledge and complete commissioning fast.

 