Huawei Network Products One Stop Shopping, Global Delivering.
| | |
Buyer Guide
Huawei MA5616
    Share-mail Share-In Share-facebook Share-Twitter
Huawei MA5616
Huawei MA5616 H82BZ1MABA03 service subrack
5 reviews Write a Review
Price: US $--

Description: Huawei SmartAX MA5616, 19inch, with 2U height 4 service slots, support GE, GPON, EPON and 10G PON Uplink; H82BZ1MABA03 subrack
Quantity: In Stock
Overview

Huawei MA5616 H82BZ1MABA03 subrack comes with 1 PCS power cable, 1 PCS earth cable, 2 PCS mount ear, accessory package

Huawei MA5616 2U Height Remote Multi Dwelling Unit

Chassis supports 4 Service Slots

Support one power slot, with DC Power or AC Power

Support Uplink available at GE, GPON, EPON and 10GPON

Support one main control board, with available at CCUB, CCUC, CCUD, CCUE

Support a maximum of 256 POTS users or 256 ADSL2+ users or 192 VDSL2 users

Support 128 POTS users and 128 ADSL2+ users simultaneously by using a combo board

Support P2P optical access board (4GE+4FE)

Popular Service Boards: ADLE (32 Ports ADSL2+), VDLE (32 Ports VDSL2), VDGE(16 Ports VDSL2) etc

Height: 2U, Width: 19 inch

MA5616 CCUE Main Control Board support Vectoring

Gross Weight: 15kgs

Dimension: 58cm*39cm*56cm

 

Huawei SmartAX MA5616 is a remote multi dwelling unit (MDU), provides broadband services on FTTB and FTTC networks. It is 2U height and 19-inch wide, the uplink can be GE, GPON, EPON or 10G GPON. MA5616 support ADSL2+,VDSL2, SHDSL, POTS, ISDN, FE and GE ports. Normally deployed as mini DSLAM to provide ADSL2+/VDSL2 to end users, it can connect to Huawei OLT through GPON, or connect to any Ethernet switch or other MA5616 via GE ports. 


Tech Specs

Specification
Network-side portCCUB: 1*GPON + 1*GE or  2*GE or 1*EPON +1*GE
CCUC: 1*GPON + 1*GE or 2*GE
CCUD: 1*GPON + 1*GE
CCUE: 2*GPON/GE Adaptive or 1*GE+1*10G GPON
User-side port16-channel VDSL2 over POTS (Supports 8a, 8c, 8d, 12a, 12b, 17a, and 30a spectrum profiles)
24-channel VDSL2 over POTS(Supports 8a, 8b, 8c, 8d, 12a, 12b, and 17a spectrum profiles)
24-channel VDSL2 over ISDN(Supports 8a, 8b, 8c, 8d, 12a, 12b, and 17a spectrum profiles)
32-channel VDSL2 over POTS(Supports 8a, 8b, 8c, 8d, 12a, 12b, and 17a spectrum profiles)
32-channel VDSL2 over POTS(Supports system-level Vectoring function.)
48-channel VDSL2(Supports 8a, 8b, 8c, 8d, 12a, 12b, and 17a spectrum profiles)
48-channel VDSL2(Supports system-level Vectoring function)
64-channel POTS board
32-channel POTS board
8-channel ISDN board
16-channel G.SHDSL board (supporting ATM and PTM)
16-channel FE (electrical) board
P2P board with 4 GE (combo of optical port and electrical port) + 4 FE (optical port)
32-channel ADSL2+ board (built-in SPL)
64-channel ADSL2+ board (built-in SPL)
32-channel combo board (32 × POTS + 32 × ADSL2+)
Operating temperature-40℃ to 65℃; startup at -25℃
Humidity5% to 95% (non-condensing)
Heat dissipation modeProviding fans for heat dissipation. The rotating speed can be automatically adjusted.
Power supplyAC: 220 V/110 V, DC: -48 V
Backup powerSupport for 48-V backup power Support for lead-acid batteries and LiFePO4 batteries
Feature List
Layer 2 managementMAC address management
VLAN management
Flow bundle
Layer 2 forwarding policies: Outer VLAN+MAC forwarding
Layer 2 forwarding policies: Service VLAN (S-VLAN)+customer VLAN (C-VLAN) forwarding
Layer 2 isolation
Layer 2 bridging
Transparent transmission of protocol packets
1:1 virtual MAC address (VMAC)
N:1 VMAC
Quality of service (QoS)Traffic classification policies
Priority processing
Traffic policing
Congestion control
Access control list (ACL) policies
Emulation servicesPPPoE dialup emulation
Dynamic Host Configuration Protocol (DHCP) dialup emulation
Call emulation
Multicast service emulation
Layer 3 featuresDHCP Client
Address Resolution Protocol (ARP)
Domain name service (DNS) client
Static route
MulticastInternet Group Management Protocol (IGMP) version 2 or version 3 proxy and snooping
Multicast users
Multicast logs
Port-based multicast connection admission control (CAC)
IPv6IPv6 traffic classification
IPv6 ACL
DHCPv6 layer 2
IPv6 basic protocol stack
IPv6 basic routing
IPv6 neighbor discovery (ND)
IPv6 security
IPv6 multicast listener discovery (MLD)
The CCUB control board does not support IPv6 features.
Voice servicesH.248
Session Initiation Protocol (SIP)
Semi-permanent connections (SPCs)
Voice signal processing
Voice service test and maintenance
Reliability of voice services
ISDN BRAH.248
SIP
ISDN attendant system (H.248 is used)
Networking featuresMultiple Spanning Tree Protocol (MSTP)
Link Aggregation Control Protocol (LACP)
Layer 2 virtual private network (L2VPN)
PON type B protection
GPON type C protection
User securityPolicy Information Transfer Protocol (PITP)
DHCP option 82
Relay agent info option (RAIO)
MAC address anti-flapping
MAC address anti-spoofing
IP address anti-spoofing
Access user isolation
Ring check
802.1X authentication
Note: The CCUB control board does not support 802.1X authentication.
System securitySource MAC address filtering
Destination MAC address filtering
Denial of service (DoS) anti-attack
IP packet anti-attack
Internet Control Message Protocol (ICMP) packet anti-attack
Source route filtering
Firewall
Blacklist
Permitted or denied address segment
Service overload control
Operation and maintenance securitySNMP
SSH
User management
Remote connection security
Log management
Line securityAdvanced Encryption Standard (AES) 128 encryption for GPON downstream transmission
AES 128 encryption for 10G GPON downstream transmission
Note: Only the CCUD and CCUE support AES128 encryption.
Operation and maintenance featuresEthernet operations, administration and maintenance (OAM), including connectivity fault management (CFM) and Ethernet in the first mile (EFM)
Enabling or disabling ETH OAM 802.1ag globally
Y.1731-defined CFM
Y.1731-defined bidirectional diagnosis tests, including bit error rate (BER) tests
Access Node Control Protocol (ANCP)
Single-ended loop test (SELT)
Metallic loop test (MELT)
NOTE: Only the VCMM and VDMM service boards support MELT.
Batch dynamic line management (DLM) performance statistics measurement
Line optimization
Startup time optimization
Local operation and maintenance
Remote operation and user management
Version and data management
Device exception management
GPON MxU authentication
Remote DHCP software commissioning for GE upstream transmission
Remote network access control (NAC) software commissioning for GE upstream transmission
N2510 intelligent diagnosis
Clock featuresNetwork time synchronization
Line clocks recovered on upstream ports
Environment monitoringProviding one environment monitoring port that supports four digital parameters (default: smoke, door status, surge protection, and main distribution frame)
4830 power monitoring
SMU
MiniESC
Mechanical Specifications
Dimensions (H×W×D)88.1 mm x 442 mm x 245 mm (without mounting ears)
88.1 mm x 482.6 mm x 245 mm (with mounting ears)
Weight4.8 kg (empty chassis)
7.2 kg (full configuration)
Q&A

Q: Can I use MA5616 with my OLT MA5680T?

A: Yes, it supports GPON uplink, make sure you select the uplink board with GPON ports, also get the GPON SFP module for MA5616.

 

Q: Can I get technical support from thunder-link.com if we purchase MA5616 from you?

A: Yes, thunder-link.com has experienced technical team on Huawei xDSL solution, however, you may need to purchase technical support service from us as by default we only provide one year hardware warranty.

 

Q: Can I configure a MA5616 with 256 ADSL2+ ports?

A: Yes, but the 64 ADSL2+ ports board price is high, also have requirement on main control board which may make your cost high, so suggests for small site purchase the MA5616 with 128 ADSL2+, if need more than that consider big DSLAM MA5600 or 2 units MA5616 using cascading.

 

Q: Does MA5616 support vectoring?

A: Yes, but will require CCUE main control board, software will be V800R313C00, power board should be high power DC, also the VDSL2 board should be 48 ports VDSL2 board VCMM.

 

Q: What is the difference between differ MA5616 main control board?

A: As follow table:

 CCUBCCUCCCUE
Supported Daughter BoardUpstream daughter board:
GP1A
GE1A
Voice daughter board:
ADSA
ADSC
ADSM
Upstream daughter board:
UP2A
UP2C
XP1A
Voice daughter board:
ASDA
ADSC
ASDM
Upstream daughter board:
UP2A
UP2C
XP1A
Voice daughter board:
ASDA
ADSC
ASDM
Port on the Front Panel
(on the Bottom Plate)
CONSOLE
ESC
ETH
ALARM
GE0
CON/ESC
ETH
CLK/TOD
ALARM
GE
CON/ESC
ETH
CLK/TOD
ALARM
GE
 ALARM
GE
ALARM
GE
ALARM
GE
Upstream Port
(on the Daughter Plate)
When the GP1A daughter board
is configured:
GE0 (SFP port)
PON (SFF port)
When the GE1A daughter board
is configured:
GE0 (SFP port)
GE1 (SFP port)
When the UP2A or UP2C
daughter board is configured:
0 (SFP port)
1 (SFP port)
When the XP1A daughter board
is configured: 10G GPON (SFP
port)
When the UP2A or UP2C
daughter board is configured:
0 (SFP port)
1 (SFP port)
When the XP1A daughter board
is configured: 10G GPON (SFP
port)


Q: What is the difference of CCUD main control board?

A: CCUD can only be supported in MA5616 software V800R312, V800R313. Also with CCUD, MA5616 can only support 1*GPON + 1*GE uplink.


Q: Do I need to add some item if I want to configure voice on MA5616?

A: Yes, DSP subboard will need to be added if voice service required.


Q: Do I have the software when purchase the MA5616?

A: Yes, software already loaded in MA5616.


Q: Is the SFP Module included in MA5616 configuration?

A: No, it is not included, you will need to purchase additionally.


ReviewsWrite a Review

5 reviews
5

5

4

3

2

1

4

1

0

0

0

You have added

to your shopping cart

Huawei MA5616

Huawei MA5616 H82BZ1MABA03 service subrack

Price: US $--

Description:

Huawei SmartAX MA5616, 19inch, with 2U height 4 service slots, support GE, GPON, EPON and 10G PON Uplink; H82BZ1MABA03 subrack

Quantity: In Stock

Overview

Huawei MA5616 H82BZ1MABA03 subrack comes with 1 PCS power cable, 1 PCS earth cable, 2 PCS mount ear, accessory package

Huawei MA5616 2U Height Remote Multi Dwelling Unit

Chassis supports 4 Service Slots

Support one power slot, with DC Power or AC Power

Support Uplink available at GE, GPON, EPON and 10GPON

Support one main control board, with available at CCUB, CCUC, CCUD, CCUE

Support a maximum of 256 POTS users or 256 ADSL2+ users or 192 VDSL2 users

Support 128 POTS users and 128 ADSL2+ users simultaneously by using a combo board

Support P2P optical access board (4GE+4FE)

Popular Service Boards: ADLE (32 Ports ADSL2+), VDLE (32 Ports VDSL2), VDGE(16 Ports VDSL2) etc

Height: 2U, Width: 19 inch

MA5616 CCUE Main Control Board support Vectoring

Gross Weight: 15kgs

Dimension: 58cm*39cm*56cm

 

Huawei SmartAX MA5616 is a remote multi dwelling unit (MDU), provides broadband services on FTTB and FTTC networks. It is 2U height and 19-inch wide, the uplink can be GE, GPON, EPON or 10G GPON. MA5616 support ADSL2+,VDSL2, SHDSL, POTS, ISDN, FE and GE ports. Normally deployed as mini DSLAM to provide ADSL2+/VDSL2 to end users, it can connect to Huawei OLT through GPON, or connect to any Ethernet switch or other MA5616 via GE ports. 


Tech Specs
Specification
Network-side portCCUB: 1*GPON + 1*GE or  2*GE or 1*EPON +1*GE
CCUC: 1*GPON + 1*GE or 2*GE
CCUD: 1*GPON + 1*GE
CCUE: 2*GPON/GE Adaptive or 1*GE+1*10G GPON
User-side port16-channel VDSL2 over POTS (Supports 8a, 8c, 8d, 12a, 12b, 17a, and 30a spectrum profiles)
24-channel VDSL2 over POTS(Supports 8a, 8b, 8c, 8d, 12a, 12b, and 17a spectrum profiles)
24-channel VDSL2 over ISDN(Supports 8a, 8b, 8c, 8d, 12a, 12b, and 17a spectrum profiles)
32-channel VDSL2 over POTS(Supports 8a, 8b, 8c, 8d, 12a, 12b, and 17a spectrum profiles)
32-channel VDSL2 over POTS(Supports system-level Vectoring function.)
48-channel VDSL2(Supports 8a, 8b, 8c, 8d, 12a, 12b, and 17a spectrum profiles)
48-channel VDSL2(Supports system-level Vectoring function)
64-channel POTS board
32-channel POTS board
8-channel ISDN board
16-channel G.SHDSL board (supporting ATM and PTM)
16-channel FE (electrical) board
P2P board with 4 GE (combo of optical port and electrical port) + 4 FE (optical port)
32-channel ADSL2+ board (built-in SPL)
64-channel ADSL2+ board (built-in SPL)
32-channel combo board (32 × POTS + 32 × ADSL2+)
Operating temperature-40℃ to 65℃; startup at -25℃
Humidity5% to 95% (non-condensing)
Heat dissipation modeProviding fans for heat dissipation. The rotating speed can be automatically adjusted.
Power supplyAC: 220 V/110 V, DC: -48 V
Backup powerSupport for 48-V backup power Support for lead-acid batteries and LiFePO4 batteries
Feature List
Layer 2 managementMAC address management
VLAN management
Flow bundle
Layer 2 forwarding policies: Outer VLAN+MAC forwarding
Layer 2 forwarding policies: Service VLAN (S-VLAN)+customer VLAN (C-VLAN) forwarding
Layer 2 isolation
Layer 2 bridging
Transparent transmission of protocol packets
1:1 virtual MAC address (VMAC)
N:1 VMAC
Quality of service (QoS)Traffic classification policies
Priority processing
Traffic policing
Congestion control
Access control list (ACL) policies
Emulation servicesPPPoE dialup emulation
Dynamic Host Configuration Protocol (DHCP) dialup emulation
Call emulation
Multicast service emulation
Layer 3 featuresDHCP Client
Address Resolution Protocol (ARP)
Domain name service (DNS) client
Static route
MulticastInternet Group Management Protocol (IGMP) version 2 or version 3 proxy and snooping
Multicast users
Multicast logs
Port-based multicast connection admission control (CAC)
IPv6IPv6 traffic classification
IPv6 ACL
DHCPv6 layer 2
IPv6 basic protocol stack
IPv6 basic routing
IPv6 neighbor discovery (ND)
IPv6 security
IPv6 multicast listener discovery (MLD)
The CCUB control board does not support IPv6 features.
Voice servicesH.248
Session Initiation Protocol (SIP)
Semi-permanent connections (SPCs)
Voice signal processing
Voice service test and maintenance
Reliability of voice services
ISDN BRAH.248
SIP
ISDN attendant system (H.248 is used)
Networking featuresMultiple Spanning Tree Protocol (MSTP)
Link Aggregation Control Protocol (LACP)
Layer 2 virtual private network (L2VPN)
PON type B protection
GPON type C protection
User securityPolicy Information Transfer Protocol (PITP)
DHCP option 82
Relay agent info option (RAIO)
MAC address anti-flapping
MAC address anti-spoofing
IP address anti-spoofing
Access user isolation
Ring check
802.1X authentication
Note: The CCUB control board does not support 802.1X authentication.
System securitySource MAC address filtering
Destination MAC address filtering
Denial of service (DoS) anti-attack
IP packet anti-attack
Internet Control Message Protocol (ICMP) packet anti-attack
Source route filtering
Firewall
Blacklist
Permitted or denied address segment
Service overload control
Operation and maintenance securitySNMP
SSH
User management
Remote connection security
Log management
Line securityAdvanced Encryption Standard (AES) 128 encryption for GPON downstream transmission
AES 128 encryption for 10G GPON downstream transmission
Note: Only the CCUD and CCUE support AES128 encryption.
Operation and maintenance featuresEthernet operations, administration and maintenance (OAM), including connectivity fault management (CFM) and Ethernet in the first mile (EFM)
Enabling or disabling ETH OAM 802.1ag globally
Y.1731-defined CFM
Y.1731-defined bidirectional diagnosis tests, including bit error rate (BER) tests
Access Node Control Protocol (ANCP)
Single-ended loop test (SELT)
Metallic loop test (MELT)
NOTE: Only the VCMM and VDMM service boards support MELT.
Batch dynamic line management (DLM) performance statistics measurement
Line optimization
Startup time optimization
Local operation and maintenance
Remote operation and user management
Version and data management
Device exception management
GPON MxU authentication
Remote DHCP software commissioning for GE upstream transmission
Remote network access control (NAC) software commissioning for GE upstream transmission
N2510 intelligent diagnosis
Clock featuresNetwork time synchronization
Line clocks recovered on upstream ports
Environment monitoringProviding one environment monitoring port that supports four digital parameters (default: smoke, door status, surge protection, and main distribution frame)
4830 power monitoring
SMU
MiniESC
Mechanical Specifications
Dimensions (H×W×D)88.1 mm x 442 mm x 245 mm (without mounting ears)
88.1 mm x 482.6 mm x 245 mm (with mounting ears)
Weight4.8 kg (empty chassis)
7.2 kg (full configuration)
Q&A

Q: Can I use MA5616 with my OLT MA5680T?

A: Yes, it supports GPON uplink, make sure you select the uplink board with GPON ports, also get the GPON SFP module for MA5616.

 

Q: Can I get technical support from thunder-link.com if we purchase MA5616 from you?

A: Yes, thunder-link.com has experienced technical team on Huawei xDSL solution, however, you may need to purchase technical support service from us as by default we only provide one year hardware warranty.

 

Q: Can I configure a MA5616 with 256 ADSL2+ ports?

A: Yes, but the 64 ADSL2+ ports board price is high, also have requirement on main control board which may make your cost high, so suggests for small site purchase the MA5616 with 128 ADSL2+, if need more than that consider big DSLAM MA5600 or 2 units MA5616 using cascading.

 

Q: Does MA5616 support vectoring?

A: Yes, but will require CCUE main control board, software will be V800R313C00, power board should be high power DC, also the VDSL2 board should be 48 ports VDSL2 board VCMM.

 

Q: What is the difference between differ MA5616 main control board?

A: As follow table:

 CCUBCCUCCCUE
Supported Daughter BoardUpstream daughter board:
GP1A
GE1A
Voice daughter board:
ADSA
ADSC
ADSM
Upstream daughter board:
UP2A
UP2C
XP1A
Voice daughter board:
ASDA
ADSC
ASDM
Upstream daughter board:
UP2A
UP2C
XP1A
Voice daughter board:
ASDA
ADSC
ASDM
Port on the Front Panel
(on the Bottom Plate)
CONSOLE
ESC
ETH
ALARM
GE0
CON/ESC
ETH
CLK/TOD
ALARM
GE
CON/ESC
ETH
CLK/TOD
ALARM
GE
 ALARM
GE
ALARM
GE
ALARM
GE
Upstream Port
(on the Daughter Plate)
When the GP1A daughter board
is configured:
GE0 (SFP port)
PON (SFF port)
When the GE1A daughter board
is configured:
GE0 (SFP port)
GE1 (SFP port)
When the UP2A or UP2C
daughter board is configured:
0 (SFP port)
1 (SFP port)
When the XP1A daughter board
is configured: 10G GPON (SFP
port)
When the UP2A or UP2C
daughter board is configured:
0 (SFP port)
1 (SFP port)
When the XP1A daughter board
is configured: 10G GPON (SFP
port)


Q: What is the difference of CCUD main control board?

A: CCUD can only be supported in MA5616 software V800R312, V800R313. Also with CCUD, MA5616 can only support 1*GPON + 1*GE uplink.


Q: Do I need to add some item if I want to configure voice on MA5616?

A: Yes, DSP subboard will need to be added if voice service required.


Q: Do I have the software when purchase the MA5616?

A: Yes, software already loaded in MA5616.


Q: Is the SFP Module included in MA5616 configuration?

A: No, it is not included, you will need to purchase additionally.


More

Reviews Write a Review

5 4 3 2 1
4 1 0 0 0