Category Archives: Huawei OLT

How much buffer we need on the VDSF board to convert VDSL2 frame?

Issue Description Q: The MA5606T should design some buffer for frame converting.Customer has asked us how much buffer we need on the VDSF board to accomplish this request. Alarm Information Null Handling Process A: that the upstream buffer is 2M bytes and the downstream is 16M bytes. Root Cause Null Suggestions Null

TwitterLinkedInGoogle+FacebookPinterestTumblrStumbleUponRedditShare

How to change the OLT type device?

Issue Description Q: The system prompt by default is MA5680T instead of MA5600T, which means the device type is wrong. In the fact of matter, MA5680T and MA5600T are kinds of the same thing, but we clarify for customer that the MA5680T just use for GPON service, so this is the difference of commercial policy at marketing.  We have ordered MA5600T but received MA5680T. There is something wrong happened at supply of production upload, which induce us got the wrong type device.               Alarm Information Null Handling Process A: How we can change the device name on OLT. 1. log on OLT 2.Use “diagnose” and “su” mode, and Take the SCUL code (need a generated-passowrd tool, plz refer to the word in the attachment )  MA5680T#diagnose MA5680T(diagnose)%%su   Challenge:0KZQKQBT   Please input password: (here need to use that tool I mentioned before) 3.Change device type of OLT MA5680T(su)%%device MA5600T MA5680T(su)%%quit Root Cause Null Suggestions With regard to the details of operation, which how to change the type of OLT, plz check the document in the attachment.  

When the NMS Fail to Synchronize ONUs.

Keywords: ONU version information,  OLT, MA5600T&MA5603T Summary: When an NMS synchronizes with ONUs from an OLT through the FTP, the character string length of the version information (such as the equipment ID, ONT model, ONU hardware version, ONU primary software version, ONU secondary software version) reported by some ONUs exceeds the maximum length defined in the… Read More »

When Prewarning on Service Unavailability of H806GPBH & H806GPBD Boards of MA5600T

Keywords: H806GPBH, H806GPBD, DDR3 cache, slow Internet access, board reset Abstract: When a large number of users are connected to the H806GPBH/H806GPBD boards, the DDR3 read operation occasionally becomes abnormal and the external DDR3 cache returns incorrect data, causing wrong service packets. As a result, slow Internet access, dialup failure, and board reset may occur.   [Problem Description] Trigger conditions 1.… Read More »

What Is the Calculation Method for Load Balancing of the Upstream Aggregation Ports of the MA5680T?

Issue Description Q: What is the calculation method for load balancing of the upstream aggregation ports of the 5680T? Alarm Information Null Handling Process A: In the egress-ingress mode: The XOR operation is performed for the lowest three bits of the source MAC (SMAC) and the destination MAC (DMAC). A residual is obtained by dividing the XOR result by the number of aggregation ports. The residual value indicates the egress ID. Example: SMAC: 0000-1111-aabb, binary numeral corresponding to the lower 1 byte bb: 10111011, lower 3 bits: 011 DMAC: 0000-1111-ccdd, binary numeral corresponding to the lower 1 byte dd: 11011101, lower 3 bits: 101 Two aggregation ports exist. The calculation methods are as follows: The XOR operation is performed between 011 and 101 (the bit is set to 1 when the corresponding bits of two operands are different; otherwise, the bit is set to 0 in the following way): 0 1 1 1 0 1 ——- 1 1 0 The calculation result is 110 and the corresponding decimal numeral is 6. At last, the residual 0 is obtained by dividing 6 by 2, then port 0 serves as the egress. In the ingress mode: A residual is obtained by dividing the lowest three bits of the source MAC (SMAC) by the number of aggregation ports. The residual value indicates the egress ID. Example: SMAC: 0000-2222-abcd, binary numeral corresponding to the lower 1 byte cd: 11001101, lower 3 bits: 101, corresponding decimal numeral: 5 If two aggregation ports exist, the residual 1 is obtained by dividing 5 by 2. Then, port 1 serves as the egress. Root Cause Null Suggestions Null  

How to Assemble an IMPI on the MA5620G?

Issue Description Q: When the MA5620G provisions an SIP voice service, terminal users are often registered by shelf ID or by slot ID (such as sip:0/22/3/1/1/hw32303131EF0EC641@ims.zj.chinamobile.com). How are series of symbols like this are assembled? Alarm Information Null Handling Process A: The general format of “sip:0/22/3/1/1/hw32303131EF0EC641@ims.zj.chinamobile.com” is “sip: Channel/Port/Slot/Shelf/Rack/AN-ID@domain”, where Channel is fixed to 0, and Rack is fixed to 1. So variable parameters are only Shelf, Port, Slot, AN-ID and domain. Port indicates the port ID of a subscriber. Slot indicates the slot ID. Shelf indicates the shelf ID. AN-ID indicates the name of an access node and is set by running the raio-anid command. domain indicates the domain name, that is IMS domain name, and is set in the basic attribute home-domain of the SIP interface. Note: In terms of MA5620G, for the versions earlier than V800R305C00B133SPH006, Port, Slot, and Shelf do not indicate actual port ID, slot ID, and shelf ID, but the real ones plus 1; for the versions later than V800R305C00B133SPH006, the actual port ID, slot ID, and shelf ID comprise the IMPI. Root Cause Null Suggestions After the SIP interface is enabled, the device, carrying IMS user private ID (IMPI) information, registers to the IMS regularly. Users can view whether the IMPI assembled by the device meets the requirement by using the DBwin tool. For details of configuration, refer to the MA5620G SIP Voice Service Configuration Procedure.txt.  

What is the command lines that we can use on the OLT to detect PRTE board status

Issue Description Q: MA5600T(  MA5600V800R005C32B138)  has 2 PRTE one of them is damaged so how can we check it from command line Alarm Information ALARM 2849 FAULT MAJOR 0×15411026 ENVIRONMENTAL 2010-08-12 10:04:24 DST ALARM NAME  : Fan power fault alarm PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  0    EMU Type:  FAN Name:  Power fault Name:  Power fault DESCRIPTION : Fan power fault alarm CAUSE       : Power  fault ADVICE      : Check power Handling Process A: About the querying about the power board through command line please check below commands : If the two board boards is normal: MA5600T(config)#interface emu 0 MA5600T(config-if-fan-0)#display fan { alarm<K>|environment<K>|system<K> }:alarm Command: display fan alarm EMU ID: 0 —————————————————————————- Alarm name                    Alarm state —————————————————————————- Read temperature fault       Normal Fan block                            Normal Temperature high              Normal Power fault                         Normal —————————————————————————- If one of the power board is failure or does not exists MA5600T(config-if-fan-0)#display fan alarm EMU ID: 0 —————————————————————————- Alarm name                    Alarm state —————————————————————————- Read temperature fault       Normal Fan block                             Normal Temperature high               Normal Power fault                          Alarm —————————————————————————- Root Cause null Suggestions Null

How to check service board detail information?

Issue Description Q: How we can check detail information such as manufacture date, BOM code, board type, etc… of service boards on MA5600T which have SCUB control board with V800R006C02 version… Alarm Information Null Handling Process A: Detail information of service boards we can check by following steps: 1. Log in to device 2. enter… Read More »