Tag Archives: Access network

How to Control Board Failure After an MxU Service Port Is Bound to a Rate Unlimited

Abstract: In MxU V800R306C01, V800R307C00, and V800R307C01, the MxU control board fails after the following operations are performed: Product Line: Access network product line  Product Model: MA5616 l Create a rate unlimited traffic profile (traffic table ip) through the U2000 or N2000. l Bind the traffic profile to a service port on the MxU. Restart the MxU. [Problem Description]… Read More »

TwitterLinkedInGoogle+FacebookPinterestTumblrStumbleUponRedditShare

What’s the Service Interruption on the MA5616?

During a lab test for the SmartAX MA5616 V800R307C02, a service interruption has occurred due to an exception of the logic. The root cause, however, is not yet identified after more than three months of efforts to reproduce the issue in the lab. This prewarning notice describes how to identify this issue and restore the service. Product Line: Access network     Product Model: MA5616  Problem Description Trigger conditions Use a SmartAX MA5616 V800R307C02 that is in full configuration of service boards in the test. Create a service port on each VDSL port, set up a point-to-point over Ethernet (PPPoE) connection on each service port, and send the packets. Import the configuration file to the device and activate the file multiple times, and then reset the system. Enable and disable the security function multiple times and then perform dynamic host configuration protocol (DHCP) dialup and PPPoE dialup multiple times. Symptom 1. The dialup on all service ports fails. 2. The uplink and user ports collect statistics of the received ports but the logic does not collect packet statistics. Identification method 1 The system cannot forward services and all the services are interrupted. 2 Query the statistics of the received and transmitted packets on the uplink and user ports to determine whether the packets are transmitted to the FPGA logic. 2.1 The following screen shows the command and command output for querying the statistics of the received and transmitted packets on the user port. 2.2 The following screen shows the command and command output for querying the statistics of the received and transmitted packets on the uplink port. 3 If the received packets on the uplink and user ports increase, the packets are transmitted to the FPGA logic. Then, query the statistics of the packets processed by the logic. 3.1 The following screen shows the command and command output for querying the statistics of the packets processed by the logic. 4 If the values of all statistical items do not increase, an exception occurs on the logic. Note: All the preceding four conditions must be met. Root Cause The inner status mechanism of the logic becomes abnormal, resulting in the system failure to transmit packets to the FPGA logic. As a result, the packets are discarded on the ingress port. The root cause for the abnormality of the status mechanism has not yet been identified. Impact and Risk All the services on the system are interrupted. Measures and Solutions Solution There is little probability of this issue, which has not recurred during more than three months of issue… Read More »

The Feature of Huawei MA5600

1 Abundant Port Types The Huawei MA5600 provides various network ports, service ports, and maintenance ports to meet different networking requirements. Table 1 lists the ports provided by the MA5600. Port Type Port Name Remarks Network port FE optical and electrical port The network port supports the electrical port, single-mode optical port, and multi-mode optical port. They… Read More »

Tips to buy the home broadband router

Home broadband router is a router that user number is relatively small, such as the 4LAN port router, which can supply 4 computer. To buy a home broadband router, first of all, you should need to know the brand, quality and price, so you can choose a good home broadband router. 1, The router “gateway”, or “agent”? First to determine the selected router belongs to the “gateway”, or “agent”. The fundamental difference between the two is the gateway does not have the flexible permissions configuration function, and the agent has a flexible… Read More »

How to change the MA5600T Boards

Digest: The H805ADPD, H805VDMF, H805VDRD, and H80ASHLM boards of MA5600T product need to be upgraded because their DDR1 memories are changed. Such a change is for customers using these boards. Sub-product line: Access network             Product: MA5600T Problem Description 1.Product Engineering Code Change 2.Change Strategy 1) Change Scope: The sites with H805ADPD,H805VDMF,H805VDRD,H80ASHLM boards 2) Change relation : The new boards are produced with new DDR1 memories, all the function and performance are the same ,the BOM is the same too. The boards current used in sites won’t be effected. 3) Change finish date : H805ADPD:2010-12-31.Huawei will use old DDR1 memories to product board to deliver before 2010-12-31, and please push the related office to upgrade the corresponding IO board package files and software patches as soon as possible .We will deliver the new board after 2010-12-31, and won’t be permitted to deliver the boards if the office didn’t upgrade the corresponding patches. H805VDMF, H805VDRD, H80ASHLM:2010-9-30, please push the related office to upgrade the corresponding IO board package files and software patches as soon as possible. 3. Spare part Strategy The new board as spare part Impact and Risk Functions and performances of the upgraded boards are not affected if the corresponding IO board package files and software patches were not upgraded H805ADPD:Proved by test ,the abnormal rate arrived about 30% if the board without corresponding IO board package files, exceed normal . H805VDMF,H805VDRD,H80ASHLM:Proved by test, the abnormal rate didn’t increase, but it also exist the same risk as H805ADPD board. Measures and Solutions Solution: The related office which used these kinds new boards or will switch to theses kinds new boards ,please upgrade to the corresponding IO board package files and software patches , as listed in the following table. Attachment NUll

MA5600T Reset Problem Triggered by ping -v

Summary: A running MA5600T may reset after the ping -v command is executed. Sub-Product Line: Access network    Product Family: Optical access [Problem Description] Trigger conditions: The gateway returns an ICMP Destination Unreachable message after the ping -v IP address command is executed on an MA5600T. Fault symptom: The program instruction is abnormal and the MA5600T resets. See the following example: MA5600T(config)#ping -v 10.10.10.1 PING 10.10.10.1: 56  data bytes, press CTRL_C to break   ======================== Exception Info Begin ========================   Exception Time       : 2011-02-10  16:26:51 Exception VosTick    : 10636031 Exception CpuTick    : 0×00000674 8b463a54 Exception Type       : PROGRAM EXCEPTION Exception Vector Num : 0×700 Exception Task       : Co0 (ID = 98, OsalID = 0x783c020) Exception PID        : -1 Exception CPUID      : -1 Dopra Version        : DOPRA V100R006C08SPC070 Application Version  : UnConfig   Task Stack Base      : 0×7914000 Task Stack End       : 0x790a000 Task Stack Max Size  : 0xa000 Task Stack Cur Size  : 0 Task Stack High      : 0x2d10 Task Stack Margin   : 0x72f0 Identification method: The MA5600T resets immediately the ping -v IP address command is executed. [Root Cause] ping -v requires the domain name server (DNS) to parse the domain name corresponding to the IP address of the ICMP Destination Unreachable message returned. During the domain name parsing, the hook function is not associated. As a result, the MA5600T invokes an empty hook function, causing a system reset. [Impact and Risks] All services of the reset MA5600T will be interrupted and the configurations that are not saved before the reset will be lost. [Measures and Solutions] Recovery measures: N/A Workarounds: Do not add the parameter -v when running a ping command. Solutions: The problem will be resolved in the following commercial patches: V800R006C02SPC124, to be released at the end of March 2011 V800R007C00SPC313, to be released at the end of March 2011 V800R008C01SPC104, to be released at the end of April 2011 [Rectification Scope and Time Requirements] N/A [Notice Expiration] This notice automatically expires after related patches are loaded.

Some Abnormal OLT GPON CLASS B+ Optical Modules at High Temperature

Abstract: Some OLT GPON CLASS B+ optical modules provided by SOURCE PHOTONICS may rarely become faulty after long-term working at high temperature, resulting in unstable transmit optical power, and ONUs being offline. Product Line: Access network             Product Family: OLT Product Model: MA5600T, MA5603T, MA5680T, and MA5683T [Problem Description] Trigger conditions: Optical modules have been working at the temperature higher than 60 degrees for a long term. Optical modules are OLT GPON CLASS B+ optical modules of the SPS4348HHPCDE model provided by SOURCE PHOTONICS. When the above conditions are met, 0.143% of the optical modules may have unstable transmit optical power, resulting in offline ONUs. Symptoms: Optical modules have unstable transmit optical power, resulting in offline ONUs. Identification methods: Method 1 If the ONU that connects to the PON port on a GPBD board is offline, perform the following steps to check whether the cause is the involved optical module in the warning. Check whether the optical module is working at high temperature and belongs to the SPS4348HHPCDE model. Run the command to check whether the optical module has been working at high temperature for a long term. Temperature(C)         60    —-Enclosure temperature of the involved optical module in the warning exceeds 60 degrees. Run the command or query the label on the top side of the optical module to check whether the optical module is the SPS4348HHPCDE model. Query using the command Related optical module information in the query result is as follows: Vendor PN            SPS4348HHPCDE       —-involved vendor PN Vendor name          SOURCEPHOTONICS     —-involved vendor name Query the label on the top side of the optical module. The involved information is in red blocks on the label on the top side of the optical module, as shown in Figure 1. Label on the top side of the optical module   Check whether the optical module is the involved optical module in the warning based on the transmit optical power. If the transmit optical power not in the range from 1.5 dBm to 5 dBm after multiple queries (using commands), the optical module is the involved optical module in the warning. TX power(dBm)                -10.61    —-The transmit optical power of the involved optical module is generally less than 1.5 dBm and a negative number. Query command: :display port state [ponid] MA5600T(config)#interface gpon 0/2… Read More »

Prewarning for Maintenance of the AC Power Board on the MA561x

Summary: When replacing the AC power board PAIA/PAIB on the MA5610/MA5616, if the operator removes the power board without powering off it beforehand (removing the 220 V AC power connector on the panel), there are potential safety hazards. Product Line:  Access Network                   Product Model: MA5616 Keywords: MA5610/MA5616   PAIA  PAIB  AC power board  security specifications Problem Description  Trigger conditions When replacing of the AC power board PAIA/PAIB on the MA5610/MA5616, the operator removes the AC power board without powering off the board beforehand (disconnecting the 220 V AC power plug from the panel). Symptom Removing the power board before disconnecting the 220 V power plug from the board panel causes potential safety hazards. Identification method The MA5610s/MA5616s installed with the PAIA or PAIB power boards that are delivered to sites before September 1, 2009 are affected.   Root Cause The safety specifications of the H831PAIA/H831PAIB AC power boards used on the MxUs cannot fully meet the requirements, which may produce potential safety hazards to operators who remove the power boards without complying with safety rules.   Impact and Risk There are potential safety hazards.   Measures and Solutions Preventive measures The safety specifications of the AC power boards delivered after September 2009 have been strengthened. Recovery measures Use the inspection tool to check the boards on the live network. Rectify the board with potential safety hazards. For the inspection tool script, detailed delivery data, rectification method, contact CS coordinator Xue Guoqiang (Employee ID: 98735) for China market and Nie Bo (Employee ID: 92548) for markets outside of China.   Prewarning Expiration Condition This prewarning will expire after the board check is complete.  

Number Dialing Failures If An MxU Connects To A Special Type Of Phone Set-20131010-A

Summary: In MA5616 or MA5620 (equipped with an H825EPUB control board) V800R312C00SPC201, a number fails to be dialed on some special types of phone sets. Product Line: Access network                                                         Product Family: MxU Product Model: MA5620 equipped with an H825EPUB control board and MA5616 Problem Description Trigger Conditions This issue occurs if the following conditions are met: The version of the MA5616 or the MA5620 equipped with an H825EPUB control board is V800R312C00SPC201. The phone set is not standard, such as a PHILIPS HCD1888TSD series or Telifeng HCD8618(12)TSDL Symptom In V800R312C00SPC201, dual tone multiple frequency (DTMF) dialing fails on some types of phone sets. Specifically,during the number dialing, the dial tone cannot be switched, or incorrect digit or digit missing occurs. Identification Method This issue complies with the prewarning if either of the following conditions are met: A number fails to dial after picking up the phone off the hook but can be dialed using the hands free function. A number fails to be dialed if each key is pressed for a short period of time or the redial key is pressed after picking up the phone off the hook but can be dialed if each key is pressed for a long period of time. However, the number dialing is successful if the affected phone set connects to MxU V800R308. Root Cause… Read More »