Summary: An OTU board reports the IN_PWR_HIGH alarm indicating that a resistor fails in the Source optical module. Constantly reporting the alarm does not affect services, but is perceivable. Product Line: Transport                     Product Family: WDM Product Model:  OptiX OSN 1800 OptiX OSN 6800 OptiX Metro 6100 [Problem Description] Trigger conditions: There is a low probability that an OTU board reports the IN_PWR_HIGH alarm after it has been running with an 80-km CWDM Source optical module for over a year. Symptom: An OTU board reports the IN_PWR_HIGH alarm while services are running properly. The maximum receive optical power is –7.x dBm, where x is a digit. Identification method: Verify that the following conditions are met: The OTU board is installed on the OptiX OSN 1800, OptiX Metro 6100, or OptiX OSN 6800. The model type of the optical module on the OTU board contains the “6128C-SL80” or “6128C-L80” field. The model type of the optical module can be determined by viewing the manufacturing information. Figure 1 shows the manufacturing information of an example optical module with the […]
OSN 1800
Summary There is a low probability that NEs report SWDL_NEPKGCHECK alarms when OptiX OSN 1800s are upgraded from V100R003C01SPC200 or earlier […]
Huawei OSN 1800
Summary: For Huawei transmission equipment OptiX OSN 1800 V100R003C01SPC200 (5.67.03.23) or an earlier version, services on the TNF2LQM or TNF2LDGF2 […]
Huawei Optix OSN1800 OADM
Summary An OCTL port on a TNF1SCC board can only be connected to an OCTL port on a CTL board […]