Keywords: SSN1SLQ16, MSTP, OptiX OSN 3500 [Problem Description] Trigger condition: 1. The version of an OSN 3500 NE is one of the versions listed […]
Summary:If the automatic and periodic database backup functions of an MSTP NE are disabled, NE configurations may be lost after the system control board is warm or cold reset, active and standby system control boards switch over, or the NE is restarted. [Problem Description] Trigger conditions: This problem occurs if the following conditions are met: Automatic and periodic database backup functions of the NE are disabled. After automatic and periodic database backup functions of the NE are disabled, modifications such as service configuration or ASON rerouting are made to the NE. The system control board is warm or cold reset, active and standby system control boards switch over, or the NE is restarted. Fault symptoms: After the system control board is warm or cold rest or active and standby system control boards switch over, some configurations modified after automatic and periodic database backup functions of the NE are disabled may be lost. In this case, a service board reset will result in complete or incomplete service interruption. After the NE is restarted, some configurations modified after automatic and periodic database backup functions of the NE are disabled may be lost, resulting in complete or incomplete service interruption. Identification method: This problem can be identified using the inspection tool or commands. […]
OptiX OSN 7500 II/7500/ OptiX OSN 3500/ OptiX OSN 1500 Troubleshooting: How to Troubleshoot Synchronous Ethernet Clocks The common faults regarding the synchronous Ethernet clock are as follows: A clock source cannot be properly switched and the quality of clock is low. Possible Causes l The connection at the port fails. l An alarm associated with the synchronous Ethernet clock function occurs on the network. Figure 1 Flow chart for handling a synchronous Ethernet clock fault   Procedure Step 1 Cause 1: The connection at the port fails. 1. Check whether the ETH_LOS or ETH_LINK_DOWN alarm occurs at the port. 2. If yes, clear the alarm and then check whether the fault is rectified. For details on how to clear the alarm, see the Alarms and Performance Events Reference. Step 2 Cause 2: An alarm associated with the synchronous Ethernet clock occurs on the network. 1. Check whether any alarm associated with the synchronous Ethernet clock occurs on the network. For details, see Relevant Alarms. 2. If yes, clear the alarm. For details on how to clear the alarm, see the Alarms and Performance Events Reference. Step 3 If the fault persists, contact Huawei technical support engineers to handle the fault. […]
Summary: On an OptiX OSN3500  V100R008C02SPH203 that houses active and standby system control boards, the standby system control board periodically […]
OptiX OSN 3500
Summary: When an SSN3PSXCSA (Ver.B) board is used to replace another cross-connect board, after the SSN3PSXCSA (Ver.B) board is inserted […]
OptiX OSN3500
Abstract: OptiX OSN 3500 type-III cabinets (BOM: 02113256) started to be manufactured and delivered by India Supply Center from September, […]