OSN 8800 T64

Why you can not insert SDH Boards in OSN 8800 slave subrack

Sometimes OSN8800 deploy as a SDH termination, that no need more SDH equipment to save deployment cost, instead you can directly insert SDH board in OSN8800 equipment.

Did you try this solution before? if not yet, you should try it, it can save your SDH subrack cost; if yes, we think you must meet with a problem, that when you insert the SDH board  in to a OSN8800 slave subrack, not a master subrack, it always comes with error.Hereby, thunder-link.com will share our experience how to solve this problem.

Summary:

SDH boards cannot be installed in a slave subrack of OptiX OSN 8800. Therefore, the NEs where SDH boards are installed in slave subracks need to be rectified so that the SDH boards are installed in the master subracks of the NEs.

[Problem Description]

Trigger conditions:

SDH boards are installed in a slave subrack.

Symptom:

When the NE software is being upgraded to OptiX OSN 8800 V100R007C02SPC300, the upgrade will fail and the NE will be unreachable by the NMS.
If the NMS version is U2000 V100R006C00SPC200 or later, the NMS cannot manage the SDH boards in a slave subrack.

When SDH boards are installed in a slave subrack and protection is configured, the protection switching times out. As a result, services will be affected.

Identification method:

Check whether the following types of boards are installed in a slave subrack of OptiX OSN 8800.
SSN4SLQ64, SSN3SLH41, SSN4SLO16, SSN4SLD64, SSN4SL64, SSN4SLQ16, SSN4SFD64, SSN4SF64, SSN1SF64, SSN1EHSH, SSN3EAS2, SSN4BPA

[Root Cause]

SDH boards cannot be installed in a slave subrack of OptiX OSN 8800 V100R002C02 or a later version. The product document specifically describes the specification restriction. However, the specification restriction is not applied on the equipment or NMS.
An OCS subrack cannot function as a master or slave subrack but an independent NE. The SDH boards must be installed in the same OCS subrack. For details, see section 38.5 “Planning the Master and Slave Subracks” of OptiX OSN 8800 V100R002C02 Feature Description 06.
SDH boards cannot be created on the NMS of U2000 V100R006C00SPC200 or a later version.
SDH boards are not allowed in a slave subrack of NE software version OptiX OSN  8800V100R007C02SPC300 or later.

[Impact and Risk]

If the NE software is being upgraded to OptiX OSN 8800 V100R007C02SPC300, the NE will be unreachable by the NMS.

[Measures and Solutions]

Recovery measures
Rectify the network to ensure that all SDH boards are installed in a master subrack.
Preventive measure:
No preventive measure is available.

Solutions

For new NEs, change the slave subrack where SDH boards are installed into a master subrack. For details, see the attachment.

[Rectification Scope and Time Requirements]

Global
All the boards should be rectified before 2015.

[Rectification Instructions]

Step 1.  Contact with Huawei HQ to ascertain the rectification scheme and plan.
Step 2. Collect the configuration data and backup data of NEs on the live network and send them back to Huawei HQ.
Step 3. Configure databases with the help of Huawei HQ.
Step 4. Rectify the live network.