My Cart

Mini Cart

CE12808S

CE12808S

PN: 02350HGY
RFQ
Huawei CE12808S switch with 2xMPU slots, 8xLPU slots, 4xSFU slots, 8xPower Module slots, 6xFan Module slots
- +
Authorized Partner

Authorized Partner x

Authorized Partner guaranteed or sourced from officially recognized partner. Chassis and modules come with 1 year warranty.

Original New Sealed

Original New Sealed x

Original, new and sealed switch; original packaging with seal; won't unpack the product without permission (insert the power module or replace the power supply cable).

Overview

Huawei CE12808S switch with 2xMPU slots, 8xLPU slots, 4xSFU slots, 8xPower Module slots, 6xFan Module slots

Switching capacity: 59/516  Tbps

Forwarding capacity: 34,560 Mpps

Operating voltage: AC: 90 V to 290 V DC: -40 V to -72 V HVDC: 188 V to 288 V

Max. power supply (W): 12000


Huawei CloudEngine 12800 series switches are next-generation, high-performance core switches designed for data centers and high-end campus networks. They provide stable, reliable, secure, and fast L2/L3 switching services and help build an elastic, virtual, agile, and high quality network. The CloudEngine 12800 provides as much as 178Tbit/s (scalable to 1032 Tbps) switching capacity and has up to 576*100GE, 576*40GE, 2,304*25GE, or 2,304*10GE line-rate ports.


Tech Specs

ItemDescription
Physical specifications

Dimensions (W x D x H): 442 mm x 751 mm x 708.4 mm (17.40 in. x 29.57 in. x 27.89 in. (16U))

Depth from fan module handles to the lower enclosure frame: 751 mm (29.57 in.)

Depth from fan module handles to the air filter door: 766 mm (30.16 in.)


Weight

Empty: 100 kg (220.46 lb)

Fully loaded: 196 kg (432.11 lb)

Environment parametersTemperature

Operating temperature: 0°C to 40°C (32°F to 104°F) at an altitude between 0 m and 1800 m (0 ft. and 5906 ft.)


NOTE:

When the altitude is between 1800 m and 4000 m (5906 ft. and 13123 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).


Storage temperature: -40°C to +70°C (-40°F to +158°F)

Relative humidity5% RH to 85% RH, noncondensing
Altitude< 4000 m (13123 ft.)
Noise (27°C)

≤ 78 dBA

Power specificationsPower portThe power modules are plug-and-play. Power cables are connected to sockets on the power distribution unit at the rear of the chassis.
AC power input

Rated voltage: 110 V AC/220 V AC; 50 Hz/60 Hz

Rated voltage range: 100 V AC to 120 V AC/200 V AC to 240 V AC

Maximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz

Maximum input current: 18.5 A

DC power input

Rated voltage: -48 V DC/-60 V DC

Maximum voltage range: -40 V DC to -72 V DC

Rated input current: 50 A @ -48 V DC

Maximum input current: 62 A @ -40 V DC

High-voltage DC power input

Rated voltage: 240 V DC

Rated voltage range: 188 V DC to 288 V DC

Maximum output power of AC power modules

Using PHD-3000WA power modules:

380 V three-phase AC input, 220 V single-phase AC input, or 110 V dual-live-wire AC input:

N+N backup, N+1 backup, and N+0 mode (N ≤ 4): 3000 W x 4 = 12000 W


110 V single-live-wire AC input:

N+1 backup (N ≤ 7): 1500 W x 7 = 10500 W

N+0 mode (N ≤ 8): 1500 W x 8 = 12000 W



NOTE:

If the power modules use a 110 V power source, follow these suggestions:

1. Use double live wires. In this case, the output power of a power module is 3000 W.

2. If only one live wire is used, the output power of a power module is 1500 W. In this case, it is recommended that you use more power modules or change the power module backup mode to increase the output power.

Maximum output power of DC power modules

N+N backupc (N ≤ 4): 2200 W x 4 = 8800 W

N+1 backup and N+0 mode (N ≤ 5): 2200 W x 5 = 11000 W

Maximum output power of high-voltage DC power modules

N+N backup, N+1 backup, and N+0 mode (N ≤ 4): 3000 W x 4 = 12000 W

Heat dissipationThe power modules have their own fans, which cool the power modules through front-to-back airflow.
Hot swap

The power modules are hot swappable.

Reliability and availabilityModulesPower module:

If double external power supply systems are used, the N+N backup mode is recommended.

If a single external power supply system is used, you can use more power modules or change the power module backup mode to increase the output power. To enhance system reliably, you are advised to use the N+1 backup mode.

Fan module: Fan modules work in hot backup mode. At normal temperature range, the system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
MPU: 1:1 hot standby
CMU: Not supported
Hot swap: All the power modules, fan modules, and cards support hot swap.
Chassis

Mean Time Between Failures (MTBF): 34.72 years

Mean time to repair (MTTR): 1 hour

Availability: 0.99999619


NOTE:

The preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules configured in the equipment.

Technical specificationsMaximum port density

V100R005C00 and V100R005C10: 64x100GE, 192x40GE, 768x10GEa, or 384xGE

V100R006C00: 64x100GE, 288x40GE, 1152x10GEa, or 384xGE

V200R001C00 and V200R002C50: 144x100GE, 288x40GE, 576x25GEb, 1152x10GEa, or 384xGE

V200R003C00: 288x100GE, 288x40GE, 1152x25GEb, 1152x10GEa, or 384xGE

Certification

Safety standards compliance

EMC standards compliance

Environmental standards compliance



Reviews
Write Your Own Review
You're reviewing:CE12808S
Your Rating:
Why Thunder-link.com
  •  

  •  

  •  

  •  

  •  

  •  

  •  

  •  

  •