| Specification |
| Number of slots for service board |
- DC-powered chassis: 6
- AC-powered chassis: 4
|
| Optical switching capability |
9-degree ROADM |
| Electrical switching capacity |
OTN |
- OTN+PKT+SDH: 160 Gbit/s
- OTN+SDH: 200 Gbit/s
|
| Packet service |
- 160 Gbit/s (128 Bytes)
- Packet processing capacity: 150 Mpps (64 Bytes)
|
| TDM |
Higher order: 50 Gbit/s; lower order: 20 Gbit/s |
| Maximum number of wavelengths |
DWDM |
80 wavelengths |
|
CWDM |
8 wavelengths |
| Center wavelength range |
- DWDM: 1529.16 nm to 1560.61 nm (C Band, ITU-T G.694.1)
- CWDM: 1471 nm to 1611 nm (S+C+L Band, ITU-T G.694.2)
|
| Service types |
SDH/SONET service, PDH service, OTN service, PCM service, Ethernet service, CPRI service, OBSAI service, SAN service, video service, and others |
| Max Rate per Channel |
200 Gbit/s |
| Line rate |
2.5 Gbit/s, 10 Gbit/s, 50Gbit/s, 100 Gbit/s, 200 Gbit/s |
| Maximum total of OSN 810 and OSN 850 devices managed by each OSN 1800 NE |
50
NOTE:
The quantity depends on the number of C12X5&C15Xn boards and the boards interconnected with the OSN 850 devices which are inserted in the OSN 1800 NE |
| Pluggable optical/electrical modul |
- Optical module: SFP/eSFP, XFP, SFP+, QSFP+, TXFP, CFP, CFP2, QSFP28
- Electrical module: GE SFP, FE SFP, STM-1 SFP
|
| Topology |
Point-to-point, chain, star, ring, ring-with-chain, intersecting rings, and tangent rings |
| Network level protection (OTN) |
Client 1+1 protection, intra-board 1+1 protection, ODUk SNCP, optical line protection, tributary SNCP, and LPT |
| Network level protection (packet) |
Tunnel APS, PW APS/FPS, LPT, LAG, ERPS, LMSP, packet SNCP, MRPS |
| Network level protection (TDM) |
SDH protection: SNCP, linear MSP, ring MSP
EoS protection: LAG, DLAG, LCAS, LPT, BPS, and STP/RSTP |
| Equipment level protection |
Control, cross-connect, and clock integrated board redundancy
Power supply redundancy
Fan redundancy |
| Optical power management |
ALS, AGC, OPA, IPA |
| Maintenance |
MPLS-TP OAM
ETH OAM
Port mirroring (EoS)
Port traffic mirroring (packet)
Loopback
PRBS
LLDP
|
| Easy O&M |
Optical Doctor System, Fiber Doctor System |
| Synchronization |
(OTN & Packet & SDH)
IEEE 1588v2 (OTN & Packet)
ITU-T G.8275.1/G.8273.2 (OTN & Packet) |
| ASON |
OTN network: Optical-Layer ASON (only Z2UXCL supports). |
| Power supply |
DC power input
Standard working voltage: -48V to -60V
Working voltage range: -40V to -72V
AC power input
Standard working voltage: 100V AC to 240V AC |
| Running environment |
Chassis temperature |
- Long-term running: -5°C to +50°C
- Short-terma running: -10°C to +55°C
|
| Chassis relative humidity |
- Long-term running: 5% to 85%
- Short-term running: 5% to 95%
|
| ETSI conformity |
ETSI Class 3.1
NOTE:
ETSI standards define temperature and humidity environments, where equipment is located. |
| Reliability Specifications |
MTTR (system mean repair time) |
4 hours |
| MTBF (system mean fault interval) |
129.63 years |
| Dimensions (H x D x W) |
88 mm x 220 mm x 442 mm (excluding handle) |
| Weight (empty chassis) |
3.6 kg (7.9 lb.) |
Ante
It took a long time to arrive, but it was well-packed.
Анатолий
Russia
OSN1800 II perform very well in our OA sites.
Waddell
Cambodia
2U OSN1800 subrack is what we needed, we received OSN1800 II after 5 days of payment.
Leviton
Germany
High integrated Huawei WDM OTN device, suitable size, we will power on and test next week.
Gerald
Cambodia
It takes long time much effort to get this OSN1800 II, test and upgrade, the package a little damaged when we get it.