Q: What is the difference between LS-S2326TP-EI-AC and LS-S2326TP-SI-AC?
A: Basically LS-S2326TP-SI-AC only supports simple Lay-2 access functions, while LS-S2326TP-EI-AC provides more powerful VLAN, QoS, multicast, security, authentication, and reliability functions. Here we list some feature which S2300 EI has better supports:
| Item |
LS-S2326TP-EI-AC |
LS-S2326TP-SI-AC |
| VLAN features |
Supports IEEE 802.1Q (VLAN) and 4096 VLANs.
Supports port-based VLAN.
Supports MAC-based VLAN.
Supports basic QinQ.
Supports 1:1 and N:1 VLAN switching. |
Supports IEEE 802.1Q (VLAN) and 4096 VLANs.
Supports port-based VLAN. |
| QoS |
Supports port rate limit and traffic rate limit.
Supports four queues with different priorities on each port.
Supports mapping of packets to different queues based on 802.1p.
Supports multiple algorithms including SP, WRR, and SP+WRR.
Supports traffic classification based on source MAC address, destination MAC address, source IP address, destination IP address, Layer-4 port number,protocol type, VLAN ID, Ethernet frame protocol type, and CoS.
Supports traffic-based priority marking and packet redirection. |
Supports port rate limit and traffic rate limit.
Supports four queues with different priorities on each port.
Supports mapping of packets to different queues based on 802.1p.
Supports multiple algorithms including SP, WRR, and SP+WRR. |
| IPv6 features |
Supports IPv6 host functions.
Supports static route configuration.
Supports IPv6 ACL.
Supports MLD v1/v2 snooping.
|
Supports IPv6 host functions.
Supports static route configuration. |
| Port mirroring |
Supports 1:1 or N:1 port mirroring
Supports Remote Switched Port Analyzer (RSPAN) and traffic-based Mirroring.
Supports packet forwarding on an observing port. |
Supports 1:1 or N:1 port mirroring
Supports packet forwarding on an observing port. |
| Security |
Supports IEEE 802.1X authentication and the limit on the maximum number of users on a port.
Supports dynamic ARP detection.
Supports IP Source Guard.
Supports multiple authentication methods including AAA, RADIUS, HWTACACS+, and NAC.
Supports binding of the IP address, MAC address, port number, and VLAN ID.
Support port rate limit.
Supports port isolation, port security, and sticky MAC.
Supports packet filtering.
Supports packet filtering based on MAC addresses.
Supports suppression of multicast, broadcast, and unknown single-cast packets.
Supports limit on the number of MAC addresses to be learned.
Supports CPU protectio |
Supports port isolation.
Supports suppression of multicast,broadcast, and unknown single-cast packets.
Supports CPU protection. |
| Power supply |
With some model support DC |
All model AC based |
Q: What is the difference between Huawei 2700 switch and 2300 switch?
A: Huawei S2700 target the enterprise market, S2300 target at telecom market, but most function are the same, the manufacturer did this mostly for marketing reasons as the telecom market most are big customers with better discount.
Q: Can I get technical support from Thunder-link.com if we purchase LS-S2326TP-SI-AC from you?
A: Yes, Thunder-link.com has experienced technical team on Huawei switches, however, you may need to purchase technical support service from us as by default we only provide one year hardware warranty.
Q: Why failure to create VLANIF interfaces of other VLANs?
A:
This problem is caused by the VLANIF interface corresponding to the default VLAN (VLAN 1) of the system. Therefore, you must delete the VLANIF interface of VLAN 1 before configuring VLANIF interfaces of other VLANs.
[S2300]undo interface Vlanif 1
[S2300]interface Vlanif 3
[S2300]ip address 1.1.1.1 255.255.255.252
The configuration succeeds.
Q: Does the S2300 switch support PoE?
A:
In V100R001 and V100R002, none of the Switches support the PoE function.
In V100R003C00 and later versions, the following models of the Switch support the PoE function:
Q: How to delete all configurations of the S2300?
A:
To delete all the configurations, delete the vrpcfg.cfg file from the flash memory, and then restart the S2300. The vrpcfg.cfg file cannot be deleted when it is running because it is used as the system file. To delete the file forcibly, perform the following steps:
1. Restart the S2300 and press Ctrl+B to enter the BootROM menu, and then enter the default password huawei.
2. Press Ctrl+Z to enter the hidden menu, and then select option 2 to enter flash memory.
3. Delete the vrpcfg.cfg file from the flash memory, and then restart the device.
Q: Does the S2300 support stacking?
A:
The S2300 does not support stacking. Later versions of V100R003 support the HGMP cluster.
Q: How to configure load balancing in a link aggregation group of SW2300?
A:
· V100R001
Run the load-balance { dmac | smac | smacxordmac } command in the Eth-Trunk view.
The default load balancing mode is smacxordmac.
· V100R002 and V100R003
Run the load-balance { dmac | smac | smacxordmac | sip | dip | sipxordip } command in the Eth-Trunk view.
The default load balancing mode is smacxordmac.
· V100R005 and V100R006
Run the load-balance { dst-ip | dst-mac | src-ip | src-mac | src-dst-ip | src-dst-mac } command in the Eth-Trunk view.
The default load balancing mode of the S3300HI, S5300HI, S5306, and S6300 is src-dst-ip; the default load balancing mode of other switches is src-dst-mac.