| Specification |
| Fixed port |
Twenty-four 10/100/1000Base-T ports |
| Forwarding performance |
96 Mpps |
| Extended slot |
Provide two extended slots, one for an uplink subcard and the other for a stack card. |
| MAC address table |
IEEE 802.1d compliance |
| 32K MAC address entries |
| MAC address learning and aging |
| Static, dynamic, and blackhole MAC address entries |
| Packet filtering based on source MAC addresses |
| VLAN |
4K VLANs |
| Guest VLAN and voice VLAN |
| VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports |
| 1:1 and N:1 VLAN Mapping |
| SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series) |
| Reliability |
RRPP ring topology and RRPP multi-instance |
| Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover |
| SEP |
| ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) |
| STP, RSTP, and MSTP |
| BPDU protection, root protection, and loop protection |
| E-Trunk |
| BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM |
| IP routing |
Static routing |
| RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series) |
| OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) |
| IPv6 features |
Neighbor Discovery (ND) |
| Path MTU (PMTU) |
| IPv6 ping, IPv6 tracert, and IPv6 Telnet |
| ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type |
| MLD v1/v2 snooping |
| 6to4 tunnel, ISATAP tunnel, and manually configured tunnel |
| Multicast |
IGMP v1/v2/v3 snooping and IGMP fast leave |
| Multicast forwarding in a VLAN and multicast replication between VLANs |
| Multicast load balancing among member ports of a trunk |
| Controllable multicast |
| Port-based multicast traffic statistics |
| IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) |
| QoS/ACL |
Rate limiting on packets sent and received by an interface |
| Packet redirection |
| Port-based traffic policing and two-rate three-color CAR |
| Eight queues on each port |
| WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms |
| WRED (supported by the S5710-EI and S5700-HI) |
| Re-marking of the 802.1p priority and DSCP priority |
| Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, port number, protocol type, and VLAN ID |
| Rate limiting in each queue and traffic shaping on ports |
| Security |
User privilege management and password protection |
| DoS attack defense, ARP attack defense, and ICMP attack defense |
| Binding of the IP address, MAC address, interface, and VLAN |
| Port isolation, port security, and sticky MAC |
| Blackhole MAC address entries |
| Limit on the number of learned MAC addresses |
| 802.1x authentication and limit on the number of users on an interface |
| AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC |
| SSH v2.0 |
| Hypertext Transfer Protocol Secure (HTTPS) |
| CPU defense |
| Blacklist and whitelist |
| OAM |
Supports |
| Access Security |
DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security |
| Management and maintenance |
Virtual cable test |
| Stacking |
| MAC Forced Forwarding (MFF) |
| Port mirroring and RSPAN (remote port mirroring) |
| Remote configuration and maintenance using Telnet |
| SNMP v1/v2/v3 |
| RMON |
| Web NMS |
| HGMP |
| System logs and alarms of different levels |
| 802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI) |
| GVRP |
| MUX VLAN |
| NetStream (supported by the S5710-EI, S5700-HI and S5710-HI) |
| sFlow(supported by the S5700(S)-LI/S5700-EI/S5700-HI series) |
| DDR memory |
256 MB |
| Flash memory |
32 MB |
| Mean time between failures (MTBF) |
S5700-28C-PWR-EI: 52 years when a 2x10GE card is configured; 55.4 years when a 4xGE front card is configured; 32.92 years when a 4x10GE front card is configured |
| Mean time to repair (MTTR) |
2 hours |
| Availability |
> 0.99999 |
| Surge protection: Service port protection |
PoE switch: ±1 kV in common mode |
| Surge protection: Power supply protection |
PoE switch: ±2 kV in differential mode; ±4 kV in common mode |
| Stack port |
Two stack ports available on each stack card |
| Maximum stack bandwidth (bidirectional) |
48 Gbit/s |
| RPS |
Not supported |
| PoE |
The PWR series support PoE. |
| Input DC voltage: Rated input voltage range |
-48 V DC to -60 V DC |
| Input DC voltage: Maximum voltage range |
-36 V DC to -72 V DC |
| Input AC voltage: Rated input voltage range |
100 V AC to 240 V AC, 50/60 Hz |
| Input AC voltage: Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz |
| Maximum system power consumption (100% throughput, 100% PoE loads, full speed of fans) |
S5700-28C-PWR-EI: 842 W (system power consumption: 102 W; PoE: 740 W) |
| Operating temperature |
0°C to 50°C |
| Storage temperature |
-40°C to +70°C |
| Noise under normal temperature (27°C, sound power) |
S5700-28C-PWR-EI: less than 45 dBA |
| Relative humidity |
5% RH to 95% RH, noncondensing |
| Operating altitude |
PoE switch: 0 m to 5000 m |
| EMC |
CISPR22 Class A |
| CISPR24 |
| EN55022 Class A |
| EN50024 |
| ETSI EN 300 386 Class A |
| CFR 47 FCC Part 15 Class A |
| ICES 003 Class A |
| AS/NZS CISPR22 Class A |
| IEC61000-4-2 |
| ITU-T K 20 |
| ITU-T K 44 |
| Environmental standards |
RoHS |
| REACH |
| WEEE |
| Security |
IEC 60950-1 |
| EN 60950-1/A11/A12 |
| UL 60950-1 |
| CSA C22.2 No 60950-1 |
| AS/NZS 60950.1 |
| Laser safety |
IEC60825-1 |
| IEC60825-2 |
| EN60825-1 |
| EN60825-2 |
| Dimensions (W x D x H) |
442.0 mm x 420.0 mm x 43.6 mm |
| Fully loaded |
≤ 8.5 kg |
| Empty loaded |
≤ 5 kg |