S5700-48TP-SI-DC

Huawei S5700-48T–SI-AC switch with 48-ports 1000BASE-T, including 4-ports GE SFP combo, 1 DC power fixed, 1 extension slot

in stock      3-5 days lead time

15 People watching this product now!
PN: 02352357 Category: Tag:
Authorized Partner

Authorized Partner x

Authorized Partner guaranteed or sourced from officially recognized partner. Chassis and modules come with 1 year warranty.

Original New Sealed

Original New Sealed x

Original, new and sealed switch; original packaging with seal; won't unpack the product without permission (insert the power module or replace the power supply cable).

Optical Module quality control-Test Procedure
In order to ensure that the optical module we deliver do not have compatibility problems. We will test each batch of optical modules, to avoid compatibility problems of switch to the greatest extent.
Learn More

Description

Huawei S5700-48TP-SI-DC switch with 48-ports 1000BASE-T, including 4-ports GE SFP combo

With 1 DC power fixed

With 1 extension slot

Layer 3 Ethernet switch

Forwarding perfomance: 72 Mpps

Switching capacity: 256Gbps

16K MAC address entries

 

Huawei Quidway S5700 series gigabit enterprise switches is designed for high-bandwidth access and Ethernet aggregation. Huawei Quidway S5700 can be used in various campus network scenarios: access switch, aggregation switch, gigabit access switch in Internet data center, or desktop switch to provide 1000 Mbps access for terminals.

Tech Specs
Specification
Fixed port Forty-four10/100/1000Base-T ports and four GE combo ports
Extended slot Provides an extended slot for a stack card
Forwarding performance 72 Mpps
MAC address table IEEE 802.1d compliance
16K MAC address entries
MAC address learning and aging
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
VLAN 4K VLANs
Guest VLAN and voice VLAN
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
1:1 and N:1 VLAN Mapping
SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series)
Reliability RRPP ring topology and RRPP multi-instance
Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover
SEP
ERPS(G.8032)
E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series)
STP, RSTP, and MSTP
BPDU protection, root protection, and loop protection
MPLS features Not supported
IP routing Static routing, ECMP
RIPv1, RIPv2 and RIPng
IPv6 features Neighbor Discovery (ND)
Path MTU (PMTU)
IPv6 ping, IPv6 tracert, and IPv6 Telnet
ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type
MLD v1/v2 snooping
6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series)
Multicast IGMP v1/v2/v3 snooping and IGMP fast leave
Multicast forwarding in a VLAN and multicast replication between VLANs
Multicast load balancing among member ports of a trunk
Controllable multicast
Port-based multicast traffic statistics
QoS/ACL Rate limiting on packets sent and received by an interface
Packet redirection
Port-based traffic policing and two-rate three-color CAR
Eight queues on each port
WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms
Re-marking of the 802.1p priority and DSCP priority
Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, port number, protocol type, and VLAN ID
Rate limiting in each queue and traffic shaping on ports
Security User privilege management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, interface, and VLAN
Port isolation, port security, and sticky MAC
Blackhole MAC address entries
Limit on the number of learned MAC addresses
802.1x authentication and limit on the number of users on an interface
AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC
SSH v2.0
Hypertext Transfer Protocol Secure (HTTPS)
CPU defense
Blacklist and whitelist
OAM Supports
Management and maintenance Virtual cable test
Stacking
MAC Forced Forwarding (MFF)
Port mirroring and RSPAN (remote port mirroring)
Remote configuration and maintenance using Telnet
SNMP v1/v2/v3
RMON
Web NMS
HGMP
System logs and alarms of different levels
GVRP
MUX VLAN
DDR memory 256 MB
Flash memory 32 MB
Mean time between failures (MTBF) S5700-48TP-SI-DC: 34 years
Mean time to repair (MTTR) 2 hours
Availability > 0.99999
Surge protection: Service port protection Non-PoE switch: ±2 kV in common mode
Surge protection: Power supply protection Non-PoE switch: DC: ±1 kV in differential mode; ±2 kV in common mode
Stack port Two stack ports available on each stack card
Maximum stack bandwidth (bidirectional) 48 Gbit/s
RPS Not supported
PoE The PWR series support PoE.
Input DC voltage: Rated input voltage range -48 V DC to -60 V DC
Input DC voltage: Maximum voltage range -36 V DC to -72 V DC
Maximum system power consumption (100% throughput, 100% PoE loads, full speed of fans) S5700-48TP-SI-DC: 64 W
Operating temperature 0°C to +50°C
Storage temperature -40°C to +70°C
Noise under normal temperature (27°C, sound power) S5700-48TP-SI-DC: 0
Relative humidity 5% RH to 95% RH, noncondensing
Operating altitude Non-PoE switch: DC: 0 m to 5000 m
EMC CISPR22 Class A
CISPR24
EN55022 Class A
EN50024
ETSI EN 300 386 Class A
CFR 47 FCC Part 15 Class A
ICES 003 Class A
AS/NZS CISPR22 Class A
IEC61000-4-2
ITU-T K 20
ITU-T K 44
Environmental standards RoHS
REACH
WEEE
Security IEC 60950-1
EN 60950-1/A11/A12
UL 60950-1
CSA C22.2 No 60950-1
AS/NZS 60950.1
Laser safety IEC60825-1
IEC60825-2
EN60825-1
EN60825-2
Dimensions (W x D x H) 442.0 mm x 420.0 mm x 43.6 mm
Fully loaded ≤ 8.5 kg
Empty loaded ≤ 5 kg
Additional information
Weight 8.5 kg
Dimensions 57.7 × 59.5 × 12.0 cm
PoE Type

Non-PoE

Features

,

Port

48+

Rate

GE

Q&A

Q: Does S5700-48TP-SI-DC support stack?

A: Yes, but it is not through the stack card, it is through the GE uplink interface.

V200R001: The last two uplink 1000Base-X optical ports can be used as stack ports.

V200R002 and later versions: The four uplink 1000Base-X optical ports can be used as stack ports.

 

Q: What is the difference between Huawei 5700 switch and 5300 switch?

A: Huawei S5700 target the enterprise market, S5300 target at telecom market, but most function are the same, the manufacturer did this mostly for marketing reasons as the telecom market most are big customers with better discount.

 

Q: Can an Electrical Interface of the S5700 Be Connected to an O/E Converter?

A: An optical interface of the S5700 can be connected to an O/E converter.

 

Q: Does the S5700 Interface Support 100M Optical Modules?

A: Fixed optical interfaces on the S5700-EI, S5700-SI, S5710-LI, and S5700-HI support 100M optical modules, while interfaces on extended front cards do not support 100M optical modules.

Combo optical interfaces and 100/1000Base-X optical interfaces on the S5700-LI and S5700S-LI series switches support 100M optical modules.

The S5710-EI series switches support 100M optical modules only on their combo optical interfaces.

Combo optical interfaces and 100/1000Base-X optical interfaces on the S5720-EI series switches support 100M optical modules.

In the S5720-HI series, only the S5720-32C-HI-24S-AC supports 100M optical modules on their 100/1000Base-X optical interfaces.

The S5720-SI series switches support 100M optical modules only on their combo optical interfaces.

 

Q: How Do I Know that the S5700’s Fan Operates Normally in Intelligent Mode?

A: The fans can work in the intelligent mode or forcible mode.

In the intelligent mode, the fans start to operate only when the ambient temperature goes higher than a specified value. In V200R003C00 and later versions, you can run the display fan speed-adjust threshold minus command on the switches that use the intelligent heat dissipation mode to view the temperature thresholds for the fans to start and stop running. The set fan speed-adjust threshold minus command can be used to lower these temperature thresholds.

Intelligent heat dissipation:

• S5700-24TP-SI-AC

• S5700-24TP-SI-DC

• S5700-48TP-SI-AC

• S5700-48TP-SI-DC

 

Q: Does the S5700 Support LRM Optical Modules?

A: The S5700SI supports long reach multimode (LRM) optical modules since V100R006C00SPC800. The S5700EI supports LRM optical modules since V100R006C01.

The S5700-LI (10GE optical ports), S5710-C-LI (10GE optical ports), S5700-HI (10GE optical ports), S5710-EI (10GE optical ports), and S5720-EI (only 10GE optical ports on extended interface cards) support LRM optical modules.

 

Q: Do 10GE Front Subcards of S5700 Switches Support GE/10GE Auto-Sensing?

A: The 10GE front subcards of the S5700EI do not support GE/10G auto-sensing, and 10GE front subcards of the S5700HI and S5700SI support GE/10G auto-sensing.

 

Q: Can 4*GE and 4*10GE Front Subcards of the S5700EI and S5700SI Switches Be Used Without an Extended Rear Subcard?

A: When a 4*GE or 4*10GE front subcard is used without an extended rear subcard, only two of the four ports on the subcard can be used:

• 4*GE subcard: Only the first and second ports can be initialized. The ports are displayed as GigabitEthernet */1/1 and GigabitEthernet */1/2 after initialization.

• 4*10GE subcard: Only the first and third ports can be initialized. The ports are displayed as XGigabitEthernet */1/1 and XGigabitEthernet */1/2 after initialization.

 

Q: Are the Cards of S5700 Hot Swappable?

A: Interface cards on the S5700 series except for the S5700EI and S5700SI are hot swappable.

 

Q: Why Only Two Optical Interfaces Are Displayed After a Front Card Is Installed on an S5700?

A: The reason is that no extended rear card is installed on the S5700.

An S5700-EI or S5700-SI can provide only two optical interfaces for a front card. If a 4-port front card is installed, an ETPB extended rear card must be installed to provide the other two ports. Otherwise, only two optical interfaces are displayed.

 

Q: Can the Front Card and Stack Card of the S5700C Be Used Simultaneously?

A: When a 2-port front card is installed, the front card and the stack card can be used simultaneously. If a 4-port front card (ES5D000X4S01, ES5D00G4SA01, or ES5D000G4S01) is installed, an ES5D00ETPB00 extended rear card must be installed.

 

Q: Are Subcards of the S5700SI and S5700EI Support 10GE Ports?

A: The S5700SI and S5700EI switches use front subcards to provide 10GE ports. The ES5D000X2S00 and ES5D000X4S01 front subcards provide 10GE ports on the S5700SI and S5700EI switches. They use SFP+ optical modules.

The S5700SI and S5700EI switches support the ES5D000X2S00 and ES5D000X4S01 front subcards since V100R005.

• An ES5D000X2S00 front subcard can be used without a rear subcard or together with a rear subcard supported by the switches.

• When an ES5D000X4S01 front subcard is used together with an ES5D00ETPB00 extended rear subcard of which the PCB version is VER.C, all the four ports on the ES5D000X4S01 front subcard can be used. If an ES5D000X4S01 front subcard is used without an ES5D00ETPB00 extended rear subcard or used together with a stack rear subcard, only the first and third ports on the front subcard can be used. The two ports are displayed as XGigabitEthernet */1/1 and XGigabitEthernet */1/2 in command lines.

 

Q: SW5700 Can GE Optical Ports Use 10GE Optical Modules?

A: The four uplink GE optical ports of the S5720-P-SI and S5720S-P-SI series can use 10GE optical modules, but can only be used for stack connections in this case. GE optical ports of other switch models cannot use 10GE optical modules. 100M optical ports cannot use GE or 10GE optical modules.

 

Q: Can Thunder-link.com provide MIB for Huawei S5700 switch?

A: Yes, you may contact our sales person

 

Q: Can I get technical support from Thunder-link.com if we purchase S5700-48TP-SI-DC from you?

A: Yes, Thunder-link.com has experienced technical team on Huawei switches, however, you may need to purchase technical support service from us as by default we only provide one year hardware warranty.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “S5700-48TP-SI-DC”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.

Why Thunder-link.com

10 Years Experience

As a global leading professional Huawei network hardware and solution provider, we have delivered Huawei, ZTE, Nokia, CISCO, Fiberhome, etc, equipment to 500+ customer groups in 90+ countries over the past 10 years. Know more

Premium Quality Guaranteed

Strict 3-Level Quality Control procedure: 1st-Level inspection; 2nd-Level In-stock test; 3rd-Level 24-hour pre-delivery test to guarantee premium quality. Know more

Value over price

What we offer to our customers is value rather than price. We enable customers to enjoy the benefit of our reliable delivery products and generate more value to the greatest extent. Know more

Tailored Technical Support

We provide customers with personalized and professional tech support by remote diagnosis, fault-location and troubleshooting. "We are here to help you instantly when you need it."

Flexible Payment

We continuously offer flexible payment methods such as Wire Transfer, Paypal, L/C, Western Union and Alipay, to help customer enjoy a more convenient shopping experience. Know more

Document Resource

We provide extensive document resources to guide our customers to targetly solve the problem they may meet. Know more

1-Year Warranty Guaranteed

Our products come with 1-year warranty. Customers can ask for a repair, replacement or refund for a major product failure. Know more

Fast Global Shipping

We won't stop to develop rapid and cost effective shipping options, providing the excellent experience to our global customers. Know more

One-Stop Solution

We offer not only network products but also network proposal, mainstream and cost-effective solution to assist customers eliminate the concerns.