| Technical specifications |
| Cabinet installation standards |
Can be installed in a standard 19-inch cabinet with a single door that is not less than 600 mm deep. |
| By default, Huawei A66E cabinet (600 mm deep x 2200 mm high) with the part number of 02116432 (ES1BA66E0000) is installed. |
| Huawei N68E cabinet (800 mm deep x 2200 mm high) can be used. The part number of the cabinet is 02115156 (CR5BRACK2201). |
| A Huawei cabinet is recommended. If a third-party cabinet is used, the front door of the cabinet must be equipped with an air filter, and the rear door must be equipped with no air filter (if there is an air filter, remove it). |
| Dimensions with packaging [mm] |
835(H) x 765(W) x 725(D) |
| Chassis height [U] |
13 |
| Weight with packaging [kg] |
87 |
| Weight with packaging (full configuration) [kg] |
2T bundle: 152.8 kg |
| 6.4T bundle: 154.2 kg |
| Typical power consumption (with configuration) [W] |
2T: 1684.1 W (configured with eight LPUTs and twenty 10x10GE ports and eight 10xGE ports) |
| 6.4T: 2370 W (configured with four 8x100GE ports and four 72x10GE ports) |
| Typical heat dissipation (with configuration) [BTU/hour] |
5262.6 BTU/hour (configured with eight LPUTs and twenty 10x10GE ports and eight 10xGE ports) |
| 7558.1 BTU/hour (configured with four 8x100GE ports and four 72x10GE ports) |
| MTBF |
38.41 year |
| MTTR |
0.5 hour |
| Availability |
0.999998514 |
| Power supply mode |
DC built-in |
| AC/HVDC built-in |
| Maximum number of power chassis inputs |
DC: (2 channels/PM) x 6 PMs = 12 channels |
| AC/HVDC: (1 channel/PM) x 6 PMs = 6 channels |
| Rated input voltage |
DC: –48V/–60V |
| AC: 100 V to 130 V dual-live wire/200 V to 240 V |
| HVDC: 240 V |
| Input voltage range |
DC: –40 V to –72 V |
| AC: 90 V to 290 V |
| HVDC: 190 V to 290 V |
| Heat dissipation mode |
air cooling |
| Airflow direction |
Front-to-back airflow + left-to-rear airflow |
| Noise at normal temperature (acoustic power) |
< 78 dB(A) @ 27°C |
| Number of slots |
12 |
| Number of service board slots |
8 |
| Switching capacity |
2T bundle: 11.35 Tbit/s (Calculation formula: Number of SerDeses on two SRUs x 28.125 (Serdes rate) x 64/66 (code) x 2 (bidirectional)) |
| 6.4T bundle: 28.86 Tbit/s (Calculation formula: Number of SerDeses on two SRUs x 58.125 (Serdes rate) x 64/66 (code) x 2 (bidirectional)) |
| Redundant MPUs |
1:01 |
| Redundant Switch fabrics |
1:01 |
| Redundant power supply |
DC: [2T bundle] 2+1, [6.4T bundle] 2+1 |
| AC: [2T bundle] 1+1, [6.4T bundle] 2+2 |
| Redundant fans |
Two fans are configured by default. The system can work for a short period of time if one fan fails. |
| Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
| Operating temperature |
Long-term: 0°C to 45°C (32°F to 113°F) |
| Short-term: –5°C to +55°C (23°F to 131°F) |
| Storage relative humidity |
5% RH to 95% RH, non-condensing |
| Operating relative humidity |
Long-term: 5% RH to 85% RH, non-condensing |
| Short-term: 5% RH to 95% RH, non-condensing |
| Storage altitude |
< 5000 m |
Reviews
There are no reviews yet.