Huawei S9703 AC bundle including assembly chassis EH1BS9703E00, 2xMCUA Main Board, 2x 800W AC power module
in stock 3-5 days lead time
Authorized Partner x
Authorized Partner guaranteed or sourced from officially recognized partner. Chassis and modules come with 1 year warranty.
Original New Sealed x
Original, new and sealed switch; original packaging with seal; won't unpack the product without permission (insert the power module or replace the power supply cable).
Huawei S9703 AC bundle including assembly chassis EH1BS9703E00
2xMCUA Main Board, 2x800W AC power module
With 3 service slots
Forwarding perfomance: 2160Mpps
Switching capacity: 2.88/5.76Tbps
Non-POE
S9700 series terabit routing switches (S9700 for short), high-end switches designed for nextgeneration campus networks and data centers, to implement service aggregation. Based on Huawei Versatile Routing Platform (VRP), S9700 provides high L2/L3 switching capabilities and integrates diversified services such as MPLS VPN, hardware IPv6, desktop cloud, video conferencing, and wireless access. In addition, S9700 also provides various reliability technologies including in-service software upgrade, non-stop forwarding, hardware OAM/BFD, and ring network protection. These technologies improve customers’ network operation efficiency, maximize the device running time, and reduce customers’ total cost of ownership (TCO).
Item | S9703 |
Switching capacity | 2.88/5.76 Tbit/s |
Packet forwarding rate |
2160 Mpps |
Service slots | 3 |
Wireless network management |
Native AC |
AP access control, AP region management, and AP profile management | |
Radio profile management, uniform static configuration, and centralized dynamic management |
|
Basic WLAN services, QoS, security, and user management | |
User management | unified user management |
802.1x, MAC address, and Portal authentication | |
Traffic- and time-based accounting | |
User authorization based on user groups, domains, and time ranges | |
iPCA quality awareness | Marking real service packets to obtain real-time count of dropped packets and packet loss ratio |
Counting number of dropped packets and packet loss ratio on devices and L2/L3 networks | |
SVF virtualization | Virtualizing access switches (ASs) and APs into one logical device to simplify management and maintenance |
Two layers of ASs allowed in an SVF system | |
Third-party devices allowed between SVF parent and clients | |
VLAN | Supports adding access, trunk, and hybrid interfaces to VLANs |
Supports the default VLAN | |
Supports VLAN switching | |
Supports QinQ and selective QinQ | |
Supports MAC address-based VLAN assignment | |
MAC address | Supports automatic learning and aging of MAC addresses |
Supports static, dynamic, and blackhole MAC address entries | |
Supports packet filtering based on source MAC addresses | |
Supports MAC address limiting based on ports and VLANs | |
STP/ERPS | Supports STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
Supports BPDU protection, root protection, and loop protection | |
Supports BPDU tunnel | |
ERPS (G.8032) | |
IP routing | Supports IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS |
Supports IPv6 dynamic routing protocols, such as, RIPng, OSPFv3, ISISv6, and BGP4+ |
|
Multicast | Supports IGMP v1/v2/v3, IGMPv1/v2/v3 snooping |
Supports PIM-SM, PIM-DM, PIM-SSM | |
Supports MSDP, MBGP | |
Supports prompt leave | |
Supports multicast traffic control | |
Supports multicast querier | |
Supports suppression on multicast packets | |
Supports multicast CAC, ACL | |
MPLS | Supports basic MPLS functions |
Supports MPLS OAM | |
Supports MPLS OAM | |
Supports MPLS VPN/VLL/VPLS | |
Reliability | Supports LACP and E-Trunk |
Supports VRRP and BFD for VRRP | |
Supports BFD for BGP/IS-IS/OSPF/static route | |
Supports NSF, and GR for BGP/IS-IS/OSPF/LDP | |
Supports TE FRR and IP FRR | |
Supports Ethernet OAM (IEEE 802.3ah and 802.1ag) (Hardware level) | |
Supports ITU-Y.1731 | |
Supports DLDP | |
Supports In-Service Software Upgrade (ISSU) | |
QoS | Supports traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority |
Supports actions of ACL, CAR, re-mark, and schedule | |
Supports queue scheduling algorithms, such as SP, WRR, DRR, SP+WRR, and SP+DRR |
|
Supports congestion avoidance mechanisms, such as WRED and tail drop | |
Supports H-QoS | |
Supports traffic shaping | |
Configuration and maintenance | Supports console, telnet, and SSH terminals |
Supports the network management protocols, such as SNMP v1/v2c/v3 | |
Supports file uploading and downloading using FTP and TFTP | |
Supports BootROM upgrade and remote upgrade | |
Supports hot patches | |
Supports user operation logs | |
Security and management | Supports 802.1x authentication and Portal authentication |
Supports NAC | |
Supports RADIUS and HWTACACS authentication for login users | |
Supports command line authority control based on user levels, preventing unauthorized users from using commands |
|
Supports defense against DoS attacks, TCP SYN Flood attacks, UDP Flood attacks, broadcast storms, and heavy traffic attacks | |
Supports 1K CPU queues | |
Supports ping and traceroute functions based on ICMP packets | |
Supports remote network monitoring | |
Value-added services | Supports firewall |
Supports NAT | |
Supports NetStream | |
Supports IPSec | |
Supports load balancing | |
Supports wireless AC | |
Supports IPS | |
Interoperability | Supports VBST (Compatible with PVST/PVST+/RPVST) |
Supports LNP (Similar to DTP) | |
Supports VCMP (Similar to VTP) | |
Energy saving | Supports IEEE 802.3az: Energy Efficient Ethernet (EEE) |
Dimensions(W x D x H) | 442 mm × 476 mm × 175 mm |
Chassis weight(empty) | < 15 kg |
Operating voltage | DC: –38.4 V to –72 V AC: 90 V to 290V |
Power supply capability of the equipment |
2200W |
Weight | 26.0 kg |
---|---|
Dimensions | 65.2 × 59.5 × 32.2 cm |
PoE Type |
Non-PoE |
Features | |
Rate |
100G |
Q: How are slots of an S9703 chassis distributed?
A:
Q: What are the types of the Main Control Boards of the S7700 and S9700?
A:
The main control boards of the S7700 include ES0D00MCUA00, ES0D00SRUA00, ES0D00SRUB00,and ES1D2SRUH000. The details are as follows:
The main control boards of the S9700 include EH1D2MCUAC00, EH1D2SRUDC00, EH1D2SRUDC01, and EH1D2SRUC000. The details are as follows:
Q: Are the Main Control Boards and LPUs hot swappable?
A: All the main control boards and LPUs of the S7700&S9700 are hot swappable. In addition, the fans and power supplies are hot swappable.
The ES0D00FSUA00, ES02VSTSA, EH1D2VS08000 and ES1D2VS04000 are not hot swappable.
Q: Does the S7700 and S9700 support hot backup?
A: The S7700&S9700 supports hot backup. When the master main control board fails, the S7700&S9700 automatically switches services to the slave board without interrupting the services. The software versions of the master board and slave board must be the same.
Q: Does the GE optical LPU of the S7700 and S9700 support 100M optical module?
A: Yes, the S7700&S9700’s GE optical LPU supports both 100M optical modules and 1000M optical modules.
When a 100M optical module is used, you must run the speed 100 command on the interface to set the interface rate to 100 Mbit/s.
When using a GE optical module, an interface works at 1000 Mbit/s by default. If auto-negotiation is enabled on the interface, the interface speed cannot be set to 100 Mbit/s. If auto-negotiation is disabled, you can run the speed 100 command to set the interface speed to 100 Mbit/s.The 100M optical interface can only use the 100M optical module, and the default interface rate is 100M.
When two optical interfaces are interconnected, they must use the same type of optical module.
Q: What are the differences between the E series, F series, and S series LPUs of the S7700 and S9700?
A: S7700&S9700 LPUs are classified into three series: E series, F series, and S series.
The E series is the enhanced series, and supports Multiprotocol Label Switching (MPLS) and extension of routing, ACL, and MAC address entries. The E series consists of the EA, EC, ED, and EE LPUs.
The F series is the ordinary series, and supports MPLS but not extension of MAC address entries. The F series consists of the FA and FC LPUs.
The S series is the standard series and does not support extension of MAC address entries. The S series consists of the SA and SC LPUs. The SA LPUs do not support MPLS, whereas the SC LPUs support MPLS.
Q: Does S9700 support DAD of IPv6 Link-Local addresses?
A: S9700 supports DAD of IPv6 link-local addresses from the V200R001 version.
Q: What operations should be performed when error statistics are displayed on the S9700 series switches interface?
A: If the optical interface is used, check the optical module of the interface, the full duplex status of the local end and the peer end, and the fiber. You can replace the optical module of the interface and test the S9700 Series Switches.
If the electrical interface is used, check the network cable connection and the full duplex status of the local end and the peer end.
Q: Can GE optical modules and GE electrical modules be installed on the same interface board of the S9700?
A: GE optical modules and GE electrical modules can be installed on the same 1000M optical interface board of the S9700, but you must configure the O/E converter on the 1000M optical interface board.
The 1000M optical interface board of the S9700 can use only the Huawei certified converter. When O/E converters of other vendors are installed on interfaces of the S9700, the interfaces still work as optical interfaces.
Q: What are the functions of the CF card of the S7700 and S9700?
A: The S7700&S9700 series switches support standard CF cards. The default capacity of a CF card is 512 MB, expandable to 1 GB or 2 GB. The CF card is used to store system files, configuration files, paf, License, and log files.
The S7700&S9700 series switches can start by using the startup file in the CF card. In this case, the system software package is stored on the CF card. It is required to specify the system software package on the CF card as the boot file. On the S7700&S9700 series switches, logs can be stored on the CF cards.
Q: How does S9700 write Logs to CF card?
A: The logs are cached instead of being immediately written into the log files on the CF card. The S9700 supports two methods to write the logs:
1, On S9700, the cache can store 33 KB logs. When the cache is full, the logs are written into the log file on the CF card.
2, You can also store logs to the CF card manually. That is, run the save logfile command in the user view. The information in the cache can be immediately written into the log file on the CF card.
Q: Is the CF card hot swappable?
A: The CF cards are not hot swappable.
Q: Does S9700 support the adjustment of fan speed?
A: The S9700 series switches support the adjustment of fan speed. The speed of operating fans can be automatically adjusted based on the temperature inside the chassis. In addition, you can also manually change the fan speed using the set fan-speed command. You can run the display fan command to check the status of fans.
Q: Are the power modules of the S9700 hot swappable?
A: Power modules of the S9700 are hot swappable. Before removing a power module, ensure that the chassis can work normally without the power module. When removing or installing a power module, take electrical protective measures to avoid electric shock.
Q: Does the S7700 and S9700 support the AC power supply and DC power supply?
A: AC and DC power modules or power modules of different power values cannot be installed simultaneously in the same type of power slots (system or PoE). In versions earlier than V200R006C00, the PoE slots of a switch allow only AC power modules. To use the PoE function on a switch, use AC power modules as the system power modules. In V200R006C00 and later versions, the PoE slots allow both AC and DC power modules.
Q: Does the S9700 support the optical modules of other vendors?
A: Use optical modules certified for Huawei switches. Non-certified optical modules cannot ensure transmission reliability and may affect service stability on the switch. Huawei is not responsible for any problem caused by non-certified optical modules and will not fix such problems.
As a global leading professional Huawei network hardware and solution provider, we have delivered Huawei, ZTE, Nokia, CISCO, Fiberhome, etc, equipment to 500+ customer groups in 90+ countries over the past 10 years. Know more
Strict 3-Level Quality Control procedure: 1st-Level inspection; 2nd-Level In-stock test; 3rd-Level 24-hour pre-delivery test to guarantee premium quality. Know more
What we offer to our customers is value rather than price. We enable customers to enjoy the benefit of our reliable delivery products and generate more value to the greatest extent. Know more
We provide customers with personalized and professional tech support by remote diagnosis, fault-location and troubleshooting. "We are here to help you instantly when you need it."
We continuously offer flexible payment methods such as Wire Transfer, Paypal, L/C, Western Union and Alipay, to help customer enjoy a more convenient shopping experience. Know more
We provide extensive document resources to guide our customers to targetly solve the problem they may meet. Know more
Our products come with 1-year warranty. Customers can ask for a repair, replacement or refund for a major product failure. Know more
We won't stop to develop rapid and cost effective shipping options, providing the excellent experience to our global customers. Know more
We offer not only network products but also network proposal, mainstream and cost-effective solution to assist customers eliminate the concerns.
Huawei S9703 AC bundle including assembly chassis EH1BS9703E00, 2xMCUA Main Board, 2x 800W AC power module
Whitehead Bink
Ukraine
Everything went great with this seller. No problems. Also, they offered several optics that I could not find anywhere else and the price was very reasonable. Great experience with this seller. Highly recommend.
bvert_brvedley
United Kingdom (UK)
Thunder-link is a great supplier have been buying from Thunder-link for quite some time already.