| Front Panel | |||
| There are indicators, interfaces, and a laser hazard level label on the front panel of the FIU board.
|
|||
| Valid Slot | |||
| OSN 8800 T64 subrack: The TN13FIU03 can be installed in slots IU1-IU8, IU11-IU42, IU45-IU68.
OSN 8800 T32 subrack: The TN13FIU03 can be installed in slots IU1-IU8, IU11-IU42, IU45-IU68. OSN 8800 T16 subrack: The TN13FIU03 can be installed in slots IU1-IU18. OSN 8800 platform subrack: The TN13FIU03 can be installed in slots IU1-IU18. OSN 6800 subrack: The TN13FIU03 can be installed in slots IU1-IU17. OSN 3800 subrack: The TN13FIU03 can be installed in slots IU1, IU8 and IU11. OSN 1800 I chassis: The TN13FIU03 can be installed in slot 1, slot 3, and slot 4. OSN 1800 II chassis: The TN13FIU03 can be installed in slots slot 1 to slot 7. OSN 1800 OADM frame: The TN13FIU03 can be installed in slots slot 1 to slot 4. |
|||
| Feature Code | |||
| Code | Meaning | Description | |
| First character | Band | Indicates the multiplexing solution adopted by the board. The value C represents C band; the value L represents L band. | |
| Optical Interface Parameter | |||
| – | Operating wavelength range(nm) | 1529-1561 | |
| – | Operating wavelength range of optical supervisory
channel(nm) |
1480-1520 | |
| – | Optical return loss(dB) | > 40 | |
| IN-TM RM-OUT |
Insertion loss(dB) | <= 1.5 | |
| IN-TC RC-OUT |
Insertion loss(dB) | <= 1 | |
| IN-TM | Isolation(dB) | ≥55 | |
| IN-TC | Isolation(dB) | ≥40 | |
| Polarization dependent loss(dB) | < 0.2 | ||
| Mechanical Specifications | |||
| Dimensions(mm) | 25.4(W) x 220(D) x 264.6(H) | ||
| Weight(kg) | 1 | ||