TN58NS4T51

Huawei OSN8800 100Gbit/s Line Service Processing Board (SLH,SDFEC2,Coherent,Tunable,50GHz,LC)

(5 reviews) | 6 sold | 9 QA

Out of stock      3-5 days lead time

19 People watching this product now!
PN: 03031EQH Category: Tag:
Hardware Compatibility

Hardware Compatibility x

Backed up by our experienced pre-sales support team, and volume documentation, to avoid purchasing incompatible hardware.

Hardware Tested

Hardware Tested x

In order to avoid hardware malfunction, each equipment will be strictly tested before delivery and the test report will be packed inside equipment and delivered together. Learn more

Software Compatibility

Software Compatibility x

Software compatibility test between active/standby system board, main control board and service board, mother/sub-card; system commissioning test to prevent all software conflicts.

Huawei WDM-OTN Equipment Test Procedure
In this topic, we take Huawei OSN 8800 as example to show you how to test the WDM/OTN equipment (Huawei OSN 6800 etc)
Learn More

Description

100Gbit/s Line Service Processing Board (SLH,SDFEC2,Coherent,Tunable,50GHz,LC) apply to Huawei OSN 8800.

In the general OptiX OSN 8800 T64 subrack, OptiX OSN 8800 universal platform subrack and general OptiX OSN 8800 T32 subrack, the board can work only in relay mode.

In the enhanced OptiX OSN 8800 T64 subrack, enhanced OptiX OSN8800 T32 subrack, and OptiX OSN 8800 T16 subrack, the board can work either in line mode or relay mode. When the board works in line mode, the enhanced OptiX OSN 8800 T64 subrack must use the TNK2USXH+TNK2UXCT boards and the enhanced OptiX OSN 8800 T32 subrack must use the TN52UXCH/TN52UXCM board and the OptiX OSN8800 T16 subrack must use the TN16UXCM board.

Supports mixed transmission of ODU0, ODU1, ODUflex, ODU2, ODU2e, and ODU3 signals.

Supports the cross-connection of 80 channels of ODU0/ODUflex signals or 40 channels of ODU1 signals or ten channels of ODU2/ODU2e signals or two channels of ODU3 signals or one channel of ODU4 signals between the NS4 and the cross-connect board.

Supports the OTU4 interface on the WDM side.

Supports the OTN frame format and overhead processing by referring to the ITU-T G.709.

OTU4 layer: supports the SM function.

ODUk (k=0, 1, 2, 3, 4, flex) layer: supports the PM and TCM function, and PM and TCM non-intrusive monitoring functions.

Supports ITU-T G.694.1-compliant DWDM specifications.

Supports ESC function.

Supports the PRBS function on the WDM side.

Supports SDFEC2 on the WDM side.

Supports Optical-layer ASON.

Supports Electrical-layer ASON.

Supports ODUk SNCP.

Supports intra-board 1+1 protection (when working with the OLP/DCP/QCP board).

Supports tributary SNCP protection.

Supports ODUk SPRing protection.

Supports WDM side Loopback/ODU0 Channel Loopback/ODU1 Channel Loopback/ODU2 Channel Loopback/ODU3 Channel Loopback/ODUflex Channel Loopback.

Supports hybrid transmission of the ODU0 service, ODU1 service, ODU2/ODU2e service, ODU3 service and the ODUflex service.

 

TN58NS4T51 is a 100Gbit/s Line Service Processing Board, converts 80xODU0, 40xODU1, 10xODU2, 10xODU2e, 2xODU3, 1xODU4, or 80xODUflex into one ITU-T G.694.1 OTU4 signal.

TN58NS4T31 part number is 03031EQH.

Tech Specs
Front Panel
There are indicators and interfaces on the front panel of the NS4 board.

ns4_panel_fig3_wps图片.png

Valid Slot
OptiX OSN 8800 T64 subrack: IU1-IU8, IU11-IU42, IU45-IU68.

OptiX OSN 8800 T32 subrack: IU1-IU8, IU12-IU27, IU29-IU36.

OptiX OSN 8800 T16 subrack: IU1-IU8, IU11-IU18.

OptiX OSN 8800 universal platform subrack: IU3-IU16.

WDM-side fixed optical module specifications
Parameter Value
Optical Module Type 150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN
Line code format ePDM-QPSK(SDFEC2)
Transmitter parameter specifications at point S
Center frequency(THz) 192.1 to 196.05
Maximum mean launched power(dBm) 0
Minimum mean launched power(dBm) -5
Center frequency deviation(GHz) ±2.5
Maximum -3 dB spectral width(nm) 0.3
Dispersion tolerance(back-to-back) (ps/nm) 150000
Receiver parameter specifications at point R
Receiver type PIN
Operating wavelength range(nm) 1529 to 1561
Receiver sensitivity(dBm) -16
Minimum receiver overload(dBm) 0
Maximum reflectance(dB) -27
Mechanical Specifications
Dimensions(mm) 25.4(W) x 220(D) x  264.6 (H)
Weight(kg) 1.62

 

Additional information
Weight 3.0 kg
Dimensions 37.5 × 34.0 × 7.5 cm
Bandwidth

100G

Features

, ,

Port

1-10

Q&A

Q: What are the functional version of NS4 board?

A: The available functional versions of NS4 board are TN54, TN56, TN57, TN58 and TN59.

Q: Does different version of NS4 have requirement for OSN8800 firmware version?

A: Yes, different versions of NS4 have different firmware versions, for details, please check below tables of Mappings Between the Board and Equipment:

Board Initial Versiona General 8800 T64 Subrack Enhanced 8800 T64 Subrack General 8800 T32 Subrack Enhanced 8800 T32 Subrack 8800 T16 Subrack 8800 Universal Platform Subrack 6800 Subrack 3800 Chassis
TN54NS4 V100R007C00 Y Y Y Y Y Y N N
TN56NS4 V100R008C00 Y Y Y Y Y Y N N
TN57NS4 T65: V100R009C10SPC300
Other: V100R008C10
Y Y Y Y Y Y N N
TN58NS4 T65: V100R009C10SPC200
T58/T68: V100R010C00SPC200
T31: V100R010C10SPC100
T50/T62: V100R011C00
Other: V100R009C10SPC100
Y Y Y Y Y Y N N
TN59NS4 V100R013C10 Y Y Y Y Y Y N N
a: If there is a substitution relationship between two boards and one of the boards is used to replace the other board, the device initial version supported by the replaced board takes effect. For example, when you use TN56NS4T11 to replace TN54NS4T11, TN56NS4T11 can be supported by V100R007C00.

Q: Why the NS4 board cannot converts between 80 channels of ODU0 signals and one channel of OTU4 signals?

A: Please make sure that your NS4 board board is set to Line mode; and if your NS4 is TN54 version, it needs to be added on NMS.

Q: Why NS4 cannot work in line mode on the general 8800 T64 Subrack?

A: When NS4 is applied to general OSN8800 T64 subrack, it only can work in relay mode, cannot work in line mode. Enhanced T64 subrack supports NS4 work in line mode, and it must use cross-connect board TNK2USXH+TNK2UXCT.

Below table is the NS4 supported board mode in OSN8800 subracks:

Board General 8800 T64 Subrack Enhanced 8800 T64 Subrack General 8800 T32 Subrack Enhanced 8800 T32 Subrack 8800 T16 Subrack 8800 Universal Platform Subrack
TN54NS4 relay mode line mode (TNK2USXH+TNK2UXCT )
Or relay mode
relay mode line mode (TN52UXCH/TN52UXCM)
Or relay mode
line mode (TN16UXCM)
Or relay mode
relay mode
TN56NS4 relay mode line mode (TNK2USXH+TNK2UXCT )
Or relay mode
line mode
(TN52UXCH/TN52UXCM, “OSN 8800 T32 standard subrack speedup (per subrack)” license must be configured)
Or relay mode
line mode (TN52UXCH/TN52UXCM)
Or relay mode
line mode (TN16UXCM) relay mode
TN57NS4 relay mode line mode (TNK2USXH+TNK2UXCT )
Or relay mode
relay mode line mode (TN52UXCH/TN52UXCM)
Or relay mode
Or relay mode relay mode
TN58NS4 relay mode line mode (TNK2USXH+TNK2UXCT )
Or relay mode
relay mode line mode (TN52UXCH/TN52UXCM)
Or relay mode
line mode (TN16UXCM)
Or relay mode
relay mode
TN59NS4 relay mode line mode (TNK2USXH+TNK2UXCT )
Or relay mode
relay mode line mode (TN52UXCH/TN52UXCM)
Or relay mode
line mode (TN16UXCM)
Or relay mode
relay mode
When NS4 works in line mode, the relative subrack must use specified cross-connect boards.
TN56NS4 can work in line mode on a general OSN 8800 T32 subrack only when OSN 8800 T32 standard subrack speedup (per subrack) license is configured.

Q: What are the differences of different hardware version?

A: Function:

Board FEC Encoding
TN54NS4 HFEC/SDFEC
TN56NS4 SDFEC
TN57NS4 HFEC/SDFEC2
TN58NS4 SDFEC2
TN59NS4 SDFEC2/FEC

Specification:

Board WDM-Side Fixed Optical Module WDM-Side Pluggable Optical Module
TN54NS4 40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(HFEC)-PIN
55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC)-PIN
N/A
TN56NS4 55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC)-PIN N/A
TN57NS4

40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(HFEC)-PIN

150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM-Enhanced)-PIN

150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM)-PIN

N/A
TN58NS4

150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM-Enhanced)-PIN

150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

120000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM)-PIN

12000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM-Metro)-PIN

120000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM)-PIN

40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM, LH)-PIN

150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, Enhanced)-PIN

N/A
TN59NS4

NA

100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, SLH+, T50)-100G CFP
100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, SLH, T51)-100G CFP
100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, SLH, high optical power, T51)-100G CFP
55000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, ULH, T52)-100G CFP
55000ps/nm-Extended C Band-Tunable Wavelength-ePDM-100G QPSK(SDFEC2, ULH, High optical power, T52)-CFP
40000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, LH, T53)-100G CFP
40000ps/nm-Extended C Band-Tunable Wavelength-ePDM-100G QPSK(SDFEC2, LH, High optical power, T53)-CFP
100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM, ULH, T61)-100G CFP
100000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM, ULH, high optical power, T61)-100G CFP
16000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2 , wDCM, Metro+, T63)-100G CFP
16000ps/nm-Extended C Band-Tunable Wavelength-ePDM-100G QPSK wDCM(SDFEC2, Metro+, High optical power, T63)-CFP
CFP-100G(4x25G/28G,Dualrate)-1295nm to 1310nm(LR4)-SMF-10km-AP

Q: What’s the board substitution relation among different versions?

A:

Original Board Substitute Board Substitution Rules
TN54NS4 TN56NS4
TN57NS4
The TN56NS4/TN57NS4 can be created as 54NS4 or 54NS4(REG) on the NMS. The former can substitute for the latter, without any software upgrade. After substitution, the TN56NS4 functions as the TN54NS4.
TN56NS4 None
TN57NS4 TN58NS4

The TN58NS4 can be created as 57NS4 on the NMS. The former can substitute for the latter, without any software upgrade. After substitution, the TN58NS4 functions as the TN57NS4.

A TN58NS4 board occupies one slot, and a TN57NS4 board occupies two slots. To use a TN58NS4 board to substitute for a TN57NS4 board, install the TN58NS4 board into the right-side slot of the two slots that the TN57NS4 board originally occupies and keep the left-side slot of them vacant

TN58NS4 TN59NS4 The TN59NS4 can be created as 58NS4 on the NMS. The former can substitute for the latter, without any software upgrade. After substitution, the TN59NS4 functions as the TN58NS4.NOTE:When both the transmit and receive boards use SDFEC2 encoding and are of the same type, they can substitute for each other. NOTE:The TN59NS4 does not support ODUk SPRing protection
TN59NS4 None

Q: Can I return/exchange board if not compatible with my system?

A: Yes, please tell our sales team your system and main control board version, before purchase.

Q: The board is new or refurbished?

A: It is original new, not been used.

Q: What is the lead time for TN58NS4T51 board?

A: In normal condition is 5 days, better to confirm with our sales team before your purchase.

Reviews (5)

5 reviews for TN58NS4T51

  1. Faisal

    5pcs NS4 are in good condition and work normally.

  2. Jan

    Thunder-link kept us informed and helped us make timely adjustments to our procurement plans. Thanks a lot!

  3. Banna
    Ireland

    Regular expansion for existing OSN8800 T32.

  4. Sebastian
    Germany

    SDFEC2 and Coherent are what we required.

  5. Sohail
    Pakistan

    Based our line side “DWDM ” requirement, Thunderlink recommends us NS4 board, meets our need well, price is affordable. Thanks for good support 🙂

Add a review

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.

Why Thunder-link.com

10 Years Experience

As a global leading professional Huawei network hardware and solution provider, we have delivered Huawei, ZTE, Nokia, CISCO, Fiberhome, etc, equipment to 500+ customer groups in 90+ countries over the past 10 years. Know more

Premium Quality Guaranteed

Strict 3-Level Quality Control procedure: 1st-Level inspection; 2nd-Level In-stock test; 3rd-Level 24-hour pre-delivery test to guarantee premium quality. Know more

Value over price

What we offer to our customers is value rather than price. We enable customers to enjoy the benefit of our reliable delivery products and generate more value to the greatest extent. Know more

Tailored Technical Support

We provide customers with personalized and professional tech support by remote diagnosis, fault-location and troubleshooting. "We are here to help you instantly when you need it."

Flexible Payment

We continuously offer flexible payment methods such as Wire Transfer, Paypal, L/C, Western Union and Alipay, to help customer enjoy a more convenient shopping experience. Know more

Document Resource

We provide extensive document resources to guide our customers to targetly solve the problem they may meet. Know more

1-Year Warranty Guaranteed

Our products come with 1-year warranty. Customers can ask for a repair, replacement or refund for a major product failure. Know more

Fast Global Shipping

We won't stop to develop rapid and cost effective shipping options, providing the excellent experience to our global customers. Know more

One-Stop Solution

We offer not only network products but also network proposal, mainstream and cost-effective solution to assist customers eliminate the concerns.