TNG1M210D

Huawei OSN 9800 M05/M12/M24 10xANY-rate MUX, 2xOTU2 Wavelength Conversion board

0 in stock      Ready to ship

13 People watching this product now!
PN: AA85C9CE Category:
Hardware Compatibility

Hardware Compatibility x

Backed up by our experienced pre-sales support team, and volume documentation, to avoid purchasing incompatible hardware.

Hardware Tested

Hardware Tested x

In order to avoid hardware malfunction, each equipment will be strictly tested before delivery and the test report will be packed inside equipment and delivered together. Learn more

Description

TNG1M210D 10xANY-rate MUX, 2xOTU2 Wavelength Conversion board

Apply to OSN 9800 M05, OSN 9800 M12 and OSN 9800 M24, it supports transponder mode and muxponder mode

TNG1M210D is mainly used to achieve wavelength tunable and to provide OTN interfaces and ESC

A maximum of three ports on a TNG1M210D board support PRBS testing. When working in ODU1_ODU0 mode, the board does not support the PRBS test function in the system direction

Supports OTU2/OTU2e on the WDM side

Supports the OTN frame format and overhead processing defined by ITU-T G.709

The M210D board is a wavelength conversion board. In the receive direction, the board can receive multiple channels of signals from client equipment, maps these optical signals into two or six channels of OTU2(e) signals, and converts the OTU2(e) signal into a standard DWDM wavelength compliant with ITU-T G.694.1. In the transmit direction, the process is reverse

Tech Specs
Front Panel
 
Valid Slots
OptiX OSN 9800 M24 subrack:In 1:1 mode: IU1-IU24; In 1:3 mode: IU1-IU5, IU8-IU17, IU20-IU24

OptiX OSN 9800 M12 subrack: IU1-IU13

OptiX OSN 9800 M05 Subrack: IU1-IU5

Initial version of different subrack:
V100R019C10SPC600
Functions and features (OTU mode)
Basic functions The M210D board supports the Transponder and Muxponder modes. In Transponder mode, the maximum output capability is 6 x OTU2(e). In MuxPonder mode, the maximum output capability is 2 x OTU2(e). The M210D converts signals as follows:
Transponder mode:
ODU2 non-convergence mode
OTU2/STM-64/FC800/10GE LAN(GFP-F)/OC192/10GE WAN/FICON8G<->ODU2<->OTU210GE LAN(BMP)/OTU2e/FC1200/FICON10G<->ODU2e<->OTU2e
Muxponder mode:
ODU0 non-convergence mode
(125Mbit/s to 1.25Gbit/s signals)<->ODU0<->(ODU1<->)ODU2<->OTU2
ODU1 non-convergence mode
(1.49Gbit/s to 2.67Gbit/s signals)<->ODU1<->ODU2<->OTU2
ODU1 convergence mode
10 x (125Mbit/s to 2.5Gbit/s signals)<->ODU1<->ODU2<->OTU2
ODU2 non-convergence mode
10GE LAN(GFP-F)/10GE WAN/STM-64/OC-192/OTU2/FC800/FICON8G<->ODU2<->OTU2
10GE LAN(BMP)/OTU2e/FC1200/FICON10G<->ODU2e<->OTU2e
ODUflex non-convergence mode
3G-SDI/3G-SDIRBR/FC400/FICON4G/FC800/FICON8G/10GE LAN(GFP-F)<->ODUflex<->ODU2<->OTU2
ODU1_ODU0 mode
OTU1<->ODU1<->2 x ODU0<->ODU1<->ODU2<->OTU2
Latency measurement Supports PM and TCM latency measurement
Supports PM and TCM latency measurement for upstream higher-order ODU channels
Supports PM and TCM latency measurement for upstream lower-order ODU channels when non-OTN services are received on the client side
Supports TCM latency measurement for downstream lower-order ODU channels when OTN services are received on the client side
WDM specification Supports ITU-T G.694.1-compliant DWDM specifications
Protection scheme Supports intra-board ODUk SNCP
Supports client 1+1 protection
Supports intra-board 1+1 protection (implemented with optical protection boards)
Tunable wavelength function The board can tune the optical signal output on the WDM side within the range of 80 wavelengths in C-band with the channel spacing of 50 GHz
Optical-layer ASON Supported
PRBS test function Supports the PRBS function on the client side
PRBS signals can be sent from the client-side optical port to the WDM side only when the client-side service type is STM-1/OC–3, STM-4/OC-12, STM-16/OC-48, OTU1, STM-64/OC-192, OTU2, OTU2e
PRBS signals can be sent from the client-side optical port to the system side when the board works in muxponder mode
Supports the PRBS function on the WDM side
Alarms and performance events monitoring Monitors BIP8 bytes (Bursty mode) to help locate line failures
Monitors B1 bytes to help locate faults
Monitors OTN alarms and performance events
Monitors parameters such as the bias current, temperature, and optical power of the laser
Supports the remote monitoring (RMON) of Ethernet services (10GE LAN)
Service encryption Supports setting the encryption function by port
OTU mode Client side:
Supports ITU-T G.709-compliant forward error correction (FEC) on the client side when the client-side service type is OTU1 or OTU2(e)
WDM side:
Supports ITU-T G.709-compliant forward error correction (FEC) on the WDM side
Supports ITU-T G.975.1-compliant AFEC-2 on the WDM side
ESC function Supported on the WDM-side. The ESC function is supported on the client side of the M210D board only when OTU1/OTU2/OTU2e signals are received
WDM-Side Pluggable Optical Module Supported
WDM-Side SFP+ -10G(with CDR)-1310nm-SMF-10km
SFP+ -10G(with CDR)-1310nm-SMF-10km
SFP+ -10G(with CDR)-1550nm-SMF-40km
SFP+ -10G(with CDR)-1550nm-SMF-80km
SFP+ -10G-(1529.17nm to 1560.61nm)(DWDM,100GHz)-SMF-40km
SFP+ -10G-(1529.17nm to 1560.61nm)(DWDM,100GHz)-SMF-80km
SFP+ -10G-(1529.17nm to 1560.61nm)(DWDM,50GHz,Tunable)-SMF-40km
SFP+ -10G(with CDR)-(1529.55nm to 1560.61nm)(DWDM,100GHz,Tunable)-SMF-40km
SFP+ -0.125G to 11.3G-1310nm-SMF-10km
Client-Side SFP+ -14G-850nm-MMF-0.1km
SFP+ -8.5G to 10.5G-850nm-MMF-0.3km
SFP+ -10G(10GE,LR/LW)-1310nm-SMF-10km
SFP+ -10G-1550nm-SMF-40km
SFP+ -10G(10GE,ZR/ZW)-1550nm-SMF-80km
SFP+ -10G(with CDR)-1310nm-SMF-10km
SFP+ -10G(with CDR)-1550nm-SMF-40km
SFP+ -10G(with CDR)-1550nm-SMF-80km
SFP+ -2.5G to 11.3G-TX1270/RX1330nm(BIDI)-SMF-10km
SFP+ -2.5G to 11.3G-TX1330/RX1270nm(BIDI)-SMF-10km
SFP-2.5G-TX1310/RX1490nm(BIDI)-SMF-40km
SFP-2.5G-TX1490/RX1310nm(BIDI)-SMF-40km
eSFP-4.25G-850nm-MMF-0.3km
eSFP-4.25G-1310nm-SMF-10km
eSFP-2.5G-(1471nm to 1611nm)(CWDM)-SMF-40km
eSFP-2.5G-(1471nm to 1611nm)(CWDM)-SMF-80km
eSFP-2.5G-TX1310/RX1490nm(BIDI)-SMF-15km
eSFP-2.5G-TX1490/RX1310nm(BIDI)-SMF-15km
eSFP-2.5G-1310nm-SMF-2km
eSFP-2.5G-1310nm-SMF-15km
eSFP-2.5G-1310nm-SMF-40km
eSFP-2.5G-1550nm-SMF-80km
eSFP-622M-1310nm-SMF-15km
eSFP-622M-1310nm-SMF-40km
eSFP-622M-1550nm-SMF-80km
eSFP-155M-1310nm-SMF-15km
eSFP-155M-1310nm-SMF-40km
eSFP-155M-1550nm-SMF-80km
eSFP-155M-1310nm-MMF-2km
eSFP-2.125G-850nm-MMF-0.5km
eSFP-1.25G-1310nm-SMF-10km
eSFP-1.25G-1310nm-SMF-40km
eSFP-1.25G-1550nm-SMF-80km
eSFP-1.25G-TX1310/RX1490nm(BIDI)-SMF-10km
eSFP-1.25G-TX1490/RX1310nm(BIDI)-SMF-10km
eSFP-1.25G-TX1310/RX1490nm(BIDI)-SMF-40km
eSFP-1.25G-TX1490/RX1310nm(BIDI)-SMF-40km
eSFP-3G-1310nm-SMF-10km
eSFP-2.5G-(1529.17nm to 1560.61nm)(DWDM,100GHz)-SMF-120km
eSFP,1550.12nm,125M~2.67Gbps,0~4.0dBm,-28.0dBm,LC,120km
SFP+ -GE(LX)/10GE(LR/LW)-1310nm-SMF-10km
SFP-1000Base-T-autonegotiation-100 m-RJ45
SFP+ -10G(with CDR)-(1471nm to 1611nm)(CWDM)-SMF-70km-I
SFP+ -0.125G to 11.3G-1310nm-SMF-10km Specifications
Mechanical Specifications
Dimensions (W x H x D,mm) 237.1×30.5x 220
Weight (kg) 1.6
Typical Power Consumption (W) 62
Maximum Power Consumption (W) 67
Additional information
Bandwidth

10G

Features

,

Port

1-10

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “TNG1M210D”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.

Why Thunder-link.com

10 Years Experience

As a global leading professional Huawei network hardware and solution provider, we have delivered Huawei, ZTE, Nokia, CISCO, Fiberhome, etc, equipment to 500+ customer groups in 90+ countries over the past 10 years. Know more

Premium Quality Guaranteed

Strict 3-Level Quality Control procedure: 1st-Level inspection; 2nd-Level In-stock test; 3rd-Level 24 hour pre-delivery test to guarantee premium quality. Know more

Value over price

What we offer to our customers is value rather than price. We make customers enjoy the benefit of our reliable delivery products and generate more value to the greatest extent. Know more

Tailored Technical Support

We provide customers personalized and professional tech support by remote diagnosis, fault-location and troubleshooting. "We are here to help you instantly when you need it."

Flexible Payment

We continuously offer flexible payment methods such as Wire Transfer, Paypal, L/C, Western Union and Alipay, to help customer enjoy a more convenient shopping experience. Know more

Official Document Resource

We provide official and extensive document resources to guide our customers to targetly solve the problem they may meet. Know more

1 Year Warranty Guaranteed

Our products come with 1 year warranty. Customers can ask for a repair, replacement or refund for a major product failure. Know more

Fast Global Shipping

We won't stop to develop rapid and cost effective shipping options, provide the excellent experience for our global customers. Know more

One Stop Solution

We provide not only network products but also network proposal, mainstream and cost efficient solution to assist customers eliminate the concerns.