| Front Panel |
 |
| Valid Slots |
| OptiX OSN 9800 M05 Subrack: IU1-IU5
OptiX OSN 9800 M12 Subrack:IU1-IU13
OptiX OSN 9800 M24 subrack: In 1:1 mode: IU1-IU24, In 1:3 mode: IU1-IU5, IU8-IU17, IU20-IU24 |
| Initial version of different subrack: |
| V100R019C10SPC600 |
| Functions and features (Muxponder mode) |
| Basic functions |
The M604SM board on the client side receives four types of signals, which are 10GE LAN, OTU4, 40GE and 100GE. The M604SM converts signals as follows: |
| 200G line: |
| 4 x 4 x 10GE<->16 x ODU2(Bit transparent mapping(11.1G IMP+BMP)/MAC transparent mapping(10.7G))<->2 x ODU4<->2 x OTU4 |
100GE<->ODU4 (Bit transparent mapping/MAC transparent mapping)<->ODUC2<->OTUC2
100GE<->ODUflex<->ODU4<->ODUC2<->OTUC2
4 x 10GE<->ODU2 (Bit transparent mapping (11.1G IMP+BMP)/MAC transparent mapping (10.7G))<-> ODU4<->ODUC2<->OTUC2
4 x 10GE<->ODUflex (MAC transparent mapping)<->ODU4<->ODUC2<->OTUC2
40GE<->ODU3 (TTT+GMP)<->ODU4<->ODUC2<->OTUC2
OTU4<->ODU4<->ODUC2<->OTUC2 |
| 4 x 40GE<->4 x ODU3(TTT+GMP)<->2 x ODU4<->2 x OTU4 |
| 400G line: |
100GE<->ODU4 (Bit transparent mapping/MAC transparent mapping)<->ODUC4<->OTUC4
100GE<->ODUflex<->ODU4<->ODUC4<->OTUC4
4 x 10GE<->ODU2 (Bit transparent mapping (11.1G IMP+BMP)/MAC transparent mapping (10.7G))<->ODU4<->ODUC4<->OTUC4
4 x 10GE<->ODUflex (MAC transparent mapping)<->ODU4<->ODUC4<->OTUC4
40GE<->ODU3 (TTT+GMP)<->ODU4<->ODUC4<->OTUC4
OTU4<->ODU4<->ODUC4<->OTUC4 |
| Latency measurement |
Supports PM and TCM latency measurement |
Supports PM and TCM latency measurement for upstream higher-order ODU channels
Supports PM and TCM latency measurement for upstream lower-order ODU channels when non-OTN services are received on the client side
Supports TCM latency measurement for downstream lower-order ODU channels when OTN services are received on the client side |
| WDM specification |
Supports DWDM specifications |
| Protection scheme |
Supports client 1+1 protection |
| Supports intra-board 1+1 protection (implemented with optical protection boards) |
| Tunable wavelength function |
M604SM supports tunable wavelengths of WDM-side optical signals in Super C band (1524 nm to 1573 nm) |
| Optical-layer ASON |
Supported |
| PRBS test function |
Supports the PRBS function on the client side |
PRBS signals can be sent from the client-side optical port to the WDM side only when the client-side service type is OTU4 and the board works in Muxponder mode
PRBS signals can be sent from the client-side optical port to the system side when client services are non-OTN services |
| Supports the PRBS function on the WDM side |
| Alarm and performance event monitoring |
Monitors BIP8 bytes (Bursty mode) to help locate line failures |
| Monitors OTN alarms and performance events |
| Monitors parameters such as the bias current, temperature, and optical power of the laser |
| Supports the remote monitoring (RMON) of Ethernet services |
| Supports the monitoring of CD and PMD performance |
| Service encryption |
When the client-side service type is 10GE/40GE/100GE, the board supports the bidirectional service encryption |
| FEC coding |
On the client side: |
Supports ITU-T G.709-compliant forward error correction (FEC) on the client side when the client-side service type is OTU4
Supports RS_FEC coding when the client-side service type is 100GE |
| On the WDM side: SDFEC2 |
| OTN function |
Supports OTUC2 or OTUC4 interfaces on the WDM side |
| Uses the frame formats and overhead processing methods defined in ITU-T G.709 |
| Supports PM and TCM overhead processing at the ODUC2/ODUC4 layer |
| At the ODU4 layer: |
Supports PM and TCM overhead processing when 100GE services are received on the client side
Supports PM and TCM overhead processing when OTU4 services are received on the client side. This board supports non-intrusive monitoring of PM and TCM overheads |
| ODU3 layer: Supports PM and TCM overhead processing |
| ODU2 layer: Supports the PM and TCM overhead processing |
| ODUflex layer: supports TCM overhead processing |
| Supports SM overhead processing at the OTU4 layer on the client side |
| Supports SM overhead processing at the OTUC2 and OTUC4 layer on the WDM side |
| ESC function |
Supported |
| Functions and features (Regeneration mode) |
| Basic function |
The M604SM board applies to electrical regeneration sites to provide the electrical regeneration function for optical signals |
| WDM specification |
Supports DWDM specifications |
| Tunable wavelength function |
M604SM supports tunable wavelengths of WDM-side optical signals in Super C band (1524 nm to 1573 nm) |
| FEC coding |
Supported |
| Regeneration rate |
OTUC2: OTN service at a rate of 224.61 Gbit/s
OTUC4: OTN service at a rate of 449.22 Gbit/s |
| Optical-layer ASON |
Supported |
| Alarm and performance event monitoring |
Monitors OTN alarms and performance events |
| Monitors parameters such as the bias current, temperature, and optical power of the laser |
| Supports CD and PMD performance monitoring |
| OTN function |
200G regeneration: |
Supports OTUC2 interfaces on the WDM side
Uses the frame formats and overhead processing methods defined in ITU-T G.709
ODUC2 layer: supports PM and TCM overhead processing, and non-intrusive monitoring of PM overheads
OTUC2 layer: supports SM overhead processing |
| 400G regeneration: |
Supports OTUC4 interfaces on the WDM side
Uses the frame formats and overhead processing methods defined in ITU-T G.709
ODUC4 layer: supports PM and TCM overhead processing, and non-intrusive monitoring of PM overheads
OTUC4 layer: supports SM overhead processing |
| WDM-Side Pluggable Optical Module Supported |
| WDM-Side(Fixed Optical Module) |
200G/400G Micro T32(SLHC,SDFEC2@200G QPSK/400G 16QAM/etc., Coherent, Tunable, Super C band, Flex grid) |
| Client-Side (Pluggable Optical Module) |
QSFP28-100G(4x25G)-850nm(SR4)-MPO-MMF-0.1km
QSFP28-100G(4x25G)-850nm(SR4)-MPO-MMF-0.1km
QSFP28-100G(4x25G)-1271 to 1331nm(CLR4)-SMF-2km
QSFP28-100G(4x25G/28G,Dualrate)-1295nm to 1310nm(LR4)-SMF-10km
QSFP28-100G(4x25G)-1310nm(ER4)-SMF-40km
QSFP+ -40G(4x10G)-850nm(SR4)-MPO-MMF-0.3km
QSFP+ -40G(4x10G)-1310nm(PSM4)-MPO-SMF-10km
QSFP+ -40G(4x10G)-1271nm to 1331nm(CWDM,LR4)-SMF-10km |
| Mechanical Specifications |
| Dimensions (W x H x D,mm) |
237.1×30.5x 220 |
| Weight (kg) |
2.5 |
| Typical Power Consumption (W) |
152 |
| Maximum Power Consumption (W) |
161 |
Małgorzata
Poland
Works as advertised, good support from thunder’s sales account