Huawei OSN 9800 U64/U32/U16 1-port 200G Line Service Processing Board
in stock inquire lead time
Hardware Compatibility x
Backed up by our experienced pre-sales support team, and volume documentation, to avoid purchasing incompatible hardware.
Hardware Tested x
In order to avoid hardware malfunction, each equipment will be strictly tested before delivery and the test report will be packed inside equipment and delivered together. Learn more
TNU2N501T11, 1-port 200 Gbit/s Line Service Processing Board
With 40000 ps/nm-C Band-Tunable Wavelength-200G-16QAM (SDFEC)-PIN fixed optical module
Apply to Huawei OptiX OSN 9800 U16/U32/U64
Functional versions of N501 are TNU1 and TNU2, and TNU1N501 or TNU2N501 has only one variant, that is TNU1N501T11 or TNU2N501T11
Supports electrical cross-connections, OTN interfaces, and ESC communication
Supports Optical-layer ASON, Electrical-layer ASON, Protection scheme and Loopback only in line mode
TNU2N501T11 is a 1-port 200G line service processing board, applied to Huawei OSN 9800 U64, OSN 9800 U32 and OSN 9800 U16. It converts 160 ODU0, 80 ODU1, 20 ODU2, 20 ODU2e, 4 ODU3, 2 ODU4, or 160 ODUflex signals into one OTUC2 signal carried over an ITU-T G.694.1 compliant DWDM wavelength, and vice versa. Each port on the board supports a mix of ODU0, ODU1, ODU2/ODU2e, ODU3, ODU4, and ODUflex signals. The N501 board uses coherent detection technology and is targeted for coherent communications.
When no capacity expansion license (Per 100G Capacity Expansion Fee) is used, the capacity of TNU2N501 is 100G. The TNU2N501 board is used to perform the following service conversion: 80 x ODU0/40 x ODU1/10 x ODU2/10 x ODU2e/2 x ODU3/1 x ODU4/80 x ODUflex <-> 1 x OTUC2. That is only one of the two ODU4 paths could be used.
Front Panel | |||||||
![]() |
|||||||
Valid Slots | |||||||
OptiX OSN 9800 U64 Standard subrack: IU1-IU64 OptiX OSN 9800 U32 Standard subrack: IU1-IU32 OptiX OSN 9800 U16 subrack: IU1-IU14 |
|||||||
Initial Version: V100R001C20SPC360 | |||||||
Line mode | |||||||
Basic function | Supports the following service conversions: 160xODU0/80xODU1/20xODU2/20xODU2e/4xODU3/2xODU4/160xODUflex<->1xOTUC2 The board supports a mix of ODU0, ODU1, ODU2, ODU2e, ODU3, ODU4 and ODUflex signals. |
||||||
Cross-connect capabilities | Supports backplane cross-connections of 160 ODU0, 80 ODU1, 20 ODU2, 20 ODU2e, 4 ODU3, 2 ODU4, or 160 ODUflex signals from/to the cross-connect board. | ||||||
License | Only the TNU2N501 board supports capacity expansion license: Per 100G Capacity Expansion Fee. The Per 100G Capacity Expansion Fee allows the TNU2N501 board to support the beyond 100G capacity function. | ||||||
OTN functions | Supports OTUC2 on the WDM side. OTUC2 layer: supports SM overhead processing. ODUC2 layer: supports PM overhead processing. ODUk (k=0, 1, 2, 2e, 3, 4, flex) layer: supports PM and TCM overhead processing, and non-intrusive monitoring of PM and TCM overheads. |
||||||
WDM specification | Supports DWDM specifications. | ||||||
Tunable wavelength function | Supports 80-wavelength-tunable optical modules. | ||||||
ESC function | Supported | ||||||
PRBS function | Supports the PRBS function on the WDM side. | ||||||
FEC coding | Supports SDFEC on the WDM side. NOTE: Boards that use different FEC modes cannot interconnect with each other. |
||||||
Alarms and performance events monitoring | Monitors BIP8 bytes (Bursty mode) to help locate line failures. Monitors parameters such as the bias current, temperature, and optical power of the laser. Monitors OTN alarms and performance events. |
||||||
Regeneration board | WDM-side signals from one N501 board can be regenerated by another N501 board. | ||||||
Test frame, IEEE 1588v2, Physical clock not supported | |||||||
Typical channel spacing | 200G 16QAM: 50 GHz Fix/37.5 GHz Superchannel | ||||||
Relay mode | |||||||
Basic function | Electrically regenerates optical signals at an electrical REG station. | ||||||
Supported service rate | OTUC2: OTN service at a rate of 224.61 Gbit/s | ||||||
OTN function | Supports the OTN frame format and overhead processing defined by ITU-T G.709. OTUC2 layer: supports SM overhead processing. ODUC2 layer: supports PM overhead processing, and non-intrusive monitoring of PM overheads. |
||||||
WDM specification | Supports DWDM specifications. | ||||||
Tunable wavelength function | Supports tunable wavelength optical modules. | ||||||
ESC function | Supported | ||||||
PRBS function | Not supported | ||||||
FEC coding | Supports SDFEC on the WDM side. NOTE: Boards that use different FEC modes cannot interconnect with each other. |
||||||
Alarms and performance events monitoring | Monitors BIP8 bytes (Bursty mode) to help locate line failures. Monitors parameters such as the bias current, temperature, and optical power of the laser. Monitors OTN alarms and performance events. |
||||||
Test frame, IEEE 1588v2, Physical clock, Optical-layer ASON, Electrical-layer ASON, Protection scheme, Loopback not supported | |||||||
40000 ps/nm-C Band-Tunable Wavelength-200G-16QAM (SDFEC)-PIN | |||||||
Optical Module Type | 200G ePDM-16QAM (SDFEC) | ||||||
Line code format | PIN | ||||||
Transmitter parameter specifications at point S | |||||||
center frequency (THz) | 192.1 to 196.05 (Fixed grid) | ||||||
center frequency (THz) | 192.09375 to 196.05625 (Flex grid) | ||||||
center frequency deviation (GHz) | ±2.5 (Fixed grid) | ||||||
center frequency deviation(GHz) | ±1.5 (Flex grid) | ||||||
minimum mean launched power (dBm) | -5 | ||||||
maximum mean launched power (dBm) | 0 | ||||||
maximum -10 db spectral width (nm) | 0.4 | ||||||
maximum -3 db spectral width (nm) | 0.3 | ||||||
dispersion tolerance (back-to-back) (ps/nm) | 40000 | ||||||
Receiver parameter specifications at point R | |||||||
receiver type | PIN | ||||||
operating wavelength range (nm) | 1529 to 1561 | ||||||
receiver sensitivity (dBm) | -16 | ||||||
minimum receiver overload(dBm) | 0 | ||||||
maximum reflectance (dB) | -27 | ||||||
Mechanical Specifications | |||||||
Dimensions (H x W x D,mm) | 477.3 x 30.5 x 220.0 | ||||||
Weight (kg) | 4 | ||||||
Typical Power Consumption (W) | 250 | ||||||
Maximum Power Consumption (W) | 265 |
Bandwidth |
200G |
---|---|
Port |
1-10 |
Features |
Q: Do TNU1N501 and TNU2N501 have 200 capacity?
A: TNU1N501 has 200G capacity;
As for TNU2N501, without capacity expansion license (Per 100G Capacity Expansion Fee): 100G
With capacity expansion license (Per 100G Capacity Expansion Fee): 200G
As a global leading professional Huawei network hardware and solution provider, we have delivered Huawei, ZTE, Nokia, CISCO, Fiberhome, etc, equipment to 500+ customer groups in 90+ countries over the past 15 years. Know more
Strict 3-Level Quality Control procedure: 1st-Level inspection; 2nd-Level In-stock test; 3rd-Level 24-hour pre-delivery test to guarantee premium quality. Know more
What we offer to our customers is value rather than price. We enable customers to enjoy the benefit of our reliable delivery products and generate more value to the greatest extent. Know more
We provide customers with personalized and professional tech support by remote diagnosis, fault-location and troubleshooting. "We are here to help you instantly when you need it."
We continuously offer flexible payment methods such as Wire Transfer, Paypal, L/C, Western Union and Alipay, to help customer enjoy a more convenient shopping experience. Know more
We provide extensive document resources to guide our customers to targetly solve the problem they may meet. Know more
Our products come with 1-year warranty. Customers can ask for a repair, replacement or refund for a major product failure. Know more
We won't stop to develop rapid and cost effective shipping options, providing the excellent experience to our global customers. Know more
We offer not only network products but also network proposal, mainstream and cost-effective solution to assist customers eliminate the concerns.
Huawei OSN 9800 U64/U32/U16 1-port 200G Line Service Processing Board
(0 reviews) | 2 sold
Reviews
There are no reviews yet.