| Specifications | |
| Valid Slots | |
| OptiX OSN 9800 U32 Enhanced:IU71 to IU77 OptiX OSN 9800 U32 Standard:IU71 to IU77 OptiX OSN 9800 U64 Enhanced:IU71 to IU77, IU79 to IU85 OptiX OSN 9800 U64 Standard:IU71 to IU77, IU79 to IU85 |
|
| Adaptation Module | |
| CXP2 AOC, 25G, 0.01km CXP2 AOC, 25G, 0.02km CXP2 AOC, 25G, 0.03km |
|
Cross-connect Capacity |
U64 Standard subrack Cross-connects a maximum of 25.6 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4 or flex) signals, and each service slot provides a cross-connect capacity of 400 Gbit/s. Performs packet switching of a maximum of 25.6 Tbit/s Ethernet services, and each service slot provides a cross-connect capacity of 400 Gbit/s. Cross-connects a maximum of 10.24 Tbit/s VC-4 signals, and each service slot provides a cross-connect capacity of 160 Gbit/s. Cross-connects a maximum of 25.6 Tbit/s OSUflex signals, and each service slot provides a cross-connect capacity of 400 Gbit/s. |
| U64 Enhanced subrack Cross-connects a maximum of 64 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4 or flex) signals, and each service slot provides a cross-connect capacity of 1 Tbit/s. Performs packet switching of a maximum of 25.6 Tbit/s Ethernet services, and each service slot provides a cross-connect capacity of 400 Gbit/s. Cross-connects a maximum of 10.24 Tbit/s VC-4 signals, and each service slot provides a cross-connect capacity of 160 Gbit/s. Cross-connects a maximum of 64 Tbit/s OSUflex signals, and each service slot provides a cross-connect capacity of 1 Tbit/s. |
|
| U32 Standard subrack Cross-connects a maximum of 12.8 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4 or flex) signals, and each service slot provides a cross-connect capacity of 400 Gbit/s. Performs packet switching of a maximum of 12.8 Tbit/s Ethernet services, and each service slot provides a cross-connect capacity of 400 Gbit/s. Cross-connects a maximum of 5.12 Tbit/s VC-4 signals, and each service slot provides a cross-connect capacity of 160 Gbit/s. Cross-connects a maximum of 12.8 Tbit/s OSUflex signals, and each service slot provides a cross-connect capacity of 400 Gbit/s. |
|
U32 Enhanced subrack
|
|
| Mechanical Specifications | |
| Dimensions (HxWxD,mm) | 477.30×30.50×220.00 |
| Weight (kg) | 3.44 |
| Typical Power Consumption (Installed in a U32 Standard/U64 Standard subrack, applicable to non-cluster scenarios) (W) | 169 |
| Typical Power Consumption (Installed in a U32 Enhanced/U64 Enhanced subrack, applicable to non-cluster scenarios)(W) | 191 |
| Typical Power Consumption (Installed in a U32 Enhanced/U64 Enhanced subrack, applicable to cluster scenarios) (W) | 250 |
| Maximum Power Consumption (Installed in a U32 Standard/U64 Standard subrack, applicable to non-cluster scenarios) (W) | 177 |
| Maximum Power Consumption (Installed in a U32 Enhanced/U64 Enhanced subrack, applicable to non-cluster scenarios) (W) | 200 |
| Maximum Power Consumption (Installed in a U32 Enhanced/U64 Enhanced subrack, applicable to cluster scenarios) (W) | 257 |


Reviews
There are no reviews yet.
There are no reviews yet.