| Specifications | |
| Valid Slots | |
| OptiX OSN 9800 U32 Enhanced, IU1 to IU32 OptiX OSN 9800 U32 Standard, IU1 to IU32 OptiX OSN 9800 U64 Enhanced, IU1 to IU64 OptiX OSN 9800 U64 Standard, IU1 to IU64 |
|
| Function and Feature | Description |
| Basic function | Performs centralized grooming of VC-3/VC-12 signals in a subrack. |
| Cross-connect Capacity | Cross-connects a maximum of 160 Gbit/s VC-3/VC-12 signals. |
| Backup mode | 1+1 backup. |
| Switching mode | Automatic switching, manual switching, and forced switching by pressing the active switching button or turning on micro switches are supported. Non-revertive switching is supported. NOTE: When a board works in active state, do not perform a cold reset on the board. Do not remove a board in active state. You must switch the board to the standby state before removing it. You can use Manual Switching on the NMS to configure the board as the standby board or press the active switching button or turn on the micro switches on the front panel to switch the board to the standby state. |
| Mechanical Specifications | |
| Dimensions (HxWxD,mm) | 477.30×30.50×220.00 |
| Weight (kg) | 2.85 |
| Typical Power Consumption (W) | 162 |
| Maximum Power Consumption (W) | 171 |