| Front Panel | |
![]() |
|
| Valid Slots | |
| OptiX OSN 9800 U16 subrack: IU1-IU14 OptiX OSN 9800 U32 Standard subrack: IU1-IU32 OptiX OSN 9800 U32 Enhanced subrack: IU1-IU32 OptiX OSN 9800 U64 Standard subrack: IU1-IU64 OptiX OSN 9800 U64 Enhanced subrack: IU1-IU64 OptiX OSN 9800 M24 subrack: (IU1, IU13), (IU2, IU14), …… , (IU11, IU23), (IU12, IU24) |
|
| Initial Version of Different Subrack | |
| U series subracks: V100R005C00 M24 subracks: V100R007C00SPC500 |
|
| Function and Features | |
| Basic functions | Supports the following service conversions: TNV1T401 board: 1x100GE(Bit Transparent Mapping)<->1xODU4 1xOTU4<->1xODU4 TNV3T401 board: 1x100GE(Bit Transparent Mapping)/(MAC Transparent Mapping)<->1xODU4 1x100GE(MAC Transparent Mapping)<->1xODUflex 1xOTU4<->1xODU4 |
| Client-side service type | 100GE: Ethernet service at a rate of 103.125 Gbit/s |
| OTU4: OTN service at a rate of 111.81 Gbit/s | |
| NOTE: When 100GE services are received on the client side and mapped into ODUflex, the client equipment must support flow control response. | |
| Cross-connect capabilities | Supports backplane cross-connections of 1 ODU4/ODUflex signal from/to the cross-connect board. |
| NOTE: Only the TNV3T401 board supports ODUflex when receiving 100GE (MAC Transparent Mapping) services on the client side. | |
| OTN functions | Supports overhead processing defined by ITU-T G.709. The service mapping process complies with ITU-T G.709 and G.Sup43. |
| ODUflex layer: supports PM overhead processing. | |
| ODU4 layer: | |
| When the client-side service type is 100GE, supports PM overhead processing. | |
| When the client-side service type is OTU4, supports PM and TCM overhead processing, and non-intrusive monitoring of PM and TCM overheads. | |
| OTU4 layer: supports SM overhead processing. | |
| ESC function | Supported when the client-side service type is OTU4. |
| FEC coding | Supports ITU-T G.709-compliant forward error correction (FEC) on the client side when the client-side service type is OTU4. |
| When the TNV3T401 board uses a converter to receive 100GE services, only RSFEC coding is supported. | |
| ALS function | When the client-side service type is 100GE, the board supports the ALS function. |
| Test frame | When the client-side service type is 100GE, the board supports test frame. |
| Latency measurement | When non-OTN services are received on the client side of the board, the PM section latency measurement is supported in the backplane direction (upstream direction). When OTN services are received on the client side of the board, the TCM section latency measurement is supported in the optical port direction (downstream direction). |
| IEEE 1588v2 | Only the TNV3T401 board supports this function when receiving 100GE(GFP-F) services on the client side. |
| ITU-T G.8275.1 | Only the TNV3T401 board supports this function when receiving 100GE(GFP-F) services on the client side. |
| ITU-T G.8273.2 | Only the TNV3T401 board of an 9800 M24 subrack supports ITU-T G.8273.2. |
| Pluggable Optical Module Supported | |
| CFP-100G(4x25G)-1295nm to 1310nm(ER4)-SMF-40km-SP CFP-100G(10x10G)-1295nm to 1550nm(LR10)-SMF-10km-SP CFP-100G(4x25G/28G,Dualrate)-1295nm to 1310nm(LR4)-SMF-10km-SP CFP-100G(4x25G)-1295nm to 1310nm(LR4)-SMF-10km-SP QSFP28-100G(4x25G)-850m(SR4)-MPO-MMF-0.1km CFP2-100G(10x10G)-850nm(SR10)-MPO-MMF-0.1km CFP2-100G(4x25G/28G,Dualrate)-1295nm to 1310nm(LR4)-SMF-10km CFP2-100G(4x25G)-1295nm to 1310nm(ER4)-SMF-40km QSFP28-100G(4x25G)-1271 to 1331nm(CLR4)-SMF-2km |
|
| Mechanical Specifications | |
| Dimensions (W x H x D, mm) | 477.3 x 30.5 x 220.0 |
| Weight (kg) | 2.4 |
| Typical Power Consumption (W) | 60 |
| Maximum Power Consumption (W) | 63 |