| Front Panel |
 |
| Valid Slots |
OptiX OSN 9800 U16 subrack: IU1-IU14
OptiX OSN 9800 U32 Standard subrack: IU1-IU32
OptiX OSN 9800 U32 Enhanced subrack: IU1-IU32
OptiX OSN 9800 U64 Standard subrack: IU1-IU64
OptiX OSN 9800 U64 Enhanced subrack: IU1-IU64
OptiX OSN 9800 M24 subrack: (IU1, IU13), (IU2, IU14), …… , (IU11, IU23), (IU12, IU24) |
| Initial Version of Different Subrack |
U series subracks: V100R002C10SPC300
M24 subracks: V100R007C00SPC500 |
| Function and Features |
| Basic functions |
Supports the following service conversions: |
| 4x100GE(Bit Transparent Mapping/(MAC Transparent Mapping))<->4xODU4 |
| 4x100GE(MAC Transparent Mapping)<->4xODUflex |
| 4xOTU4<->4xODU4 |
NOTE:
Only the TNV3T404 board supports 100GE(MAC Transparent Mapping) on the client side.
Only the TNV3T404 board supports ODUflex when receiving 100GE (MAC Transparent Mapping) services on the client side in V100R003C10SPC200 and later versions. |
| Client-side service type |
100GE: Ethernet service at a rate of 103.125 Gbit/s |
| OTU4: OTN service at a rate of 111.81 Gbit/s |
| NOTE: When 100GE services are received on the client side and mapped into ODUflex, the client equipment must support flow control response. |
| Cross-connect capabilities |
Supports backplane cross-connections of four ODU4/ODUflex signals from/to the cross-connect board. |
| OTN functions |
Supports overhead processing defined by ITU-T G.709. The service mapping process complies with ITU-T G.709 and G.Sup43. |
| ODUflex layer: supports PM overhead processing. |
| ODU4 layer: |
| When the client-side service type is 100GE, supports PM overhead processing. |
| When the client-side service type is OTU4, supports PM and TCM overhead processing, and non-intrusive monitoring of PM and TCM overheads. |
| OTU4 layer: supports SM overhead processing. |
| ESC function |
Supported when the client-side service type is OTU4. |
| LPT function |
Not supported. |
| ALS function |
When the client-side service type is 100GE, the board supports the ALS function. |
| Test frame |
When the client-side service type is 100GE, the board supports test frame. |
| Latency measurement |
When non-OTN services are received on the client side of the board, the PM section latency measurement is supported in the backplane direction (upstream direction). When OTN services are received on the client side of the board, the TCM section latency measurement is supported in the optical port direction (downstream direction). |
| IEEE 1588v2 |
Only the TNV3T404 board supports this function when receiving 100GE(GFP-F) services on the client side. |
| ITU-T G.8275.1 |
Only the TNV3T404 board supports this function when receiving 100GE(GFP-F) services on the client side. |
| ITU-T G.8273.2 |
Only the TNV3T404 board of an 9800 M24 subrack supports ITU-T G.8273.2. |
| FEC coding |
Supports ITU-T G.709-compliant forward error correction (FEC) on the client side |
| When the TNV3T404 board uses a converter to receive 100GE services, only RSFEC coding is supported. |
| Pluggable Optical Module Supported |
CFP-100G(4x25G)-1295nm to 1310nm(ER4)-SMF-40km-SP
CFP-100G(4x25G)-1295nm to 1310nm(LR4)-SMF-10km-SP
CFP-100G(4x25G/28G,Dualrate)-1295nm to 1310nm(LR4)-SMF-10km-SP
QSFP28-100G(4x25G)-850nm(SR4)-MPO-MMF-0.1km
CFP2-100G(10x10G)-850nm(SR10)-MPO-MMF-0.1km
CFP2-100G(4x25G/28G,Dualrate)-1295nm to 1310nm(LR4)-SMF-10km
CFP2-100G(4x25G)-1295nm to 1310nm(ER4)-SMF-40km
QSFP28-100G(4x25G)-1271 to 1331nm(CLR4)-SMF-2km |
| Mechanical Specifications |
| Dimensions (W x H x D, mm) |
477.3 x 30.5 x 220.0 |
| Weight (kg) |
3.35 |
| Typical Power Consumption (W) |
110 |
| Maximum Power Consumption (W) |
120 |