| Front Panel |
| There are ports on the front panel of the board.

|
| Basic functions |
| OTN signals |
1800 V: 8 x ODU0/4 x ODU1<->4 x OTU1 |
| SDH signals |
1800 V: 4 x STM-16<->4 x ODU1<->4 x OTU1 |
| Packets |
1800 V: Packets<->8 x ODU0/4 x ODU1<->4 x OTU1 |
| Clock synchronization |
OTN services: Supported (ODU0/ODU1)
SDH services: SDH clock synchronization is supported when SDH virtual ports are configured.
Packet services: Physical-layer (ODU0/ODU1) clock synchronization is supported when packet virtual ports are configured. |
| Specifications (OTN functions) |
| Basic functions |
Cross-connect functionality |
Implements service grooming when working with cross-connect boards.
ODU0/ODU1 |
| Maintenance features |
Loopbacks |
Supports system-side channel inloops and outloops.
Supports WDM-side inloops and outloops. (This function has no impact on overheads and the PRBS function.) |
| Pseudo random binary sequence (PRBS) test function |
Supported |
| Test frames |
Not supported |
| Delay measurement (DM) |
Supported |
| Alarms and performance events monitoring |
Monitors parameters such as the bias current, operating temperature, and optical power of a laser.
Monitors OTN alarms and performance events. |
| Specifications (SDH functions) |
| Service processing |
Supports VC-12, VC-3, VC-4, VC-4-4c, and VC-4-16c services (VC-4-4c and VC-4-16c services are concatenated services). |
| Overhead processing |
Processes section overheads of STM-16 signals.
Transparently transmits and terminates path overheads.
Supports the setting and querying of J0 (to be received), J1, and C2 bytes.
Provides transparent DCCs and orderwire byte channels. |
| Protection schemes |
Supports subnetwork connection protection (SNCP).
Supports subnetwork connection tunnel protection (SNCTP).
Supports linear multiplex section protection (LMSP).
Supports ring multiplex section protection (RMSP). |
| Specifications (Packet functions) |
| Service specifications |
Processing capability |
10 Gbit/s |
| Service bearing media |
MultiProtocol Label Switching Transport Profile (MPLS-TP) |
Supported |
| 802.1Q in 802.1Q (QinQ) link |
Supported |
| Port |
Supported |
| Ethernet line (E-Line) |
Native ETH service:
Point-to-point transparently transmitted E-Line service
VLAN-based E-Line service
QinQ-based E-Line service
ETH PWE3 service: PW-based E-Line service (VPWS service) |
| Ethernet local area network (E-LAN) |
Native ETH service:
E-LAN service based on the IEEE 802.1d bridge
E-LAN service based on the IEEE 802.1q bridge
ETH PWE3 service: PW-based E-LAN service (VPLS service) |
| MS-PW |
Supported |
| Jumbo frame |
Supports a jumbo frame containing a maximum of 9600 bytes. |
| Maximum frame length (MFL) for a port |
The frame length is fixed at 9600 + 72 bytes and is not configurable. |
| Maintenance features |
MPLS-TP OAM |
Supported |
| ETH-OAM |
Supports Ethernet service OAM. |
| RMON |
Supported |
| WDM-Side Pluggable Optical Module |
| XFP-2.67Gb/s-1550nm-SMF-40km |
| Version description of the UNQ1 board |
| Board |
Product Applicable-System Control Board-Initial Board Version Supported by System Control Board |
| TNZ6UNQ1 |
1800 V-TNZ5UXCMS-V100R009C00SPC500
1800 V-TNZ5XCS-V100R019C10SPC300
1800 II Enhanced-TNZ1UXCL/TNZ2UXCL-V100R009C00SPC500 |
| Mechanical Specifications |
| Typical Power Consumption(W) |
63 |
| Maximum Power Consumption(W) |
72 |
| Dimension (W x H x D, mm) |
193.8 x 19.8 x 205.9 |
| Weight(kg) |
1.2 kg |
Reviews
There are no reviews yet.
There are no reviews yet.