UPS5000-E-200 kVA
in stock inquire lead time
UPS5000-E-200 kVA
Uses a modular design, which facilitates maintenance and capacity expansion.
Adopts intelligent control.
Power module consists of a rectifier, inverter, and DC/DC converter.
Converts inputs into pure high-quality sine wave outputs by using the high-frequency switching technology.
Physical Specifications | UPS5000-E-200K-SM |
Cabling mode | Cables are routed from the top or bottom. |
IP rating | IP20 (IP21 available if the IP21 component is used) |
Dimensions (H x W x D) | 2000 mm x 600 mm x 850 mm |
Communication | Dry contacts, RS485, and SNMP |
Weight | 330 kg. A maximum of four power modules can be installed. |
Operating temperature | 0–40°C |
Storage temperature | –40°C to +70°C |
Humidity | 0%–95% RH (non-condensing) |
Altitude | 0–4000 m |
When the altitude is higher than 2000 m, the power is derated as described in IEC 62040-3. The upper limit of the altitude is 4000 m. | |
Input system | Three-phase four-wire + PE. If current is allowed in the PE wire, input without the N wire is supported. |
Rated input voltage | 380 V AC/400 V AC/415 V AC (line voltage) |
Input voltage | 80–280 V AC (phase voltage) |
At 40°C: The UPS works at full load when the voltage is 187–280 V AC and is derated to 40% load when the voltage is 187–80 V AC. | |
At 30°C: The UPS works at full load when the voltage is 176–280 V AC and is derated to 40% load when the voltage is 176–80 V AC. | |
Rated frequency | 50 Hz/60 Hz |
Input frequency | 40–70 Hz |
Input PF | > 0.99 (full load) |
> 0.98 (half load) | |
THDi | THDi ≤ 3% (full linear load) |
THDi ≤ 5% (full non-linear load) | |
Overvoltage category | OVC II |
Input system | Three-phase four-wire + PE |
Rated input voltage | 380 V AC/400 V AC/415 V AC (line voltage) |
Rated frequency | 50 Hz/60 Hz |
Input frequency | ±6 Hz (adjustable, 0.5–6 Hz, ±2 Hz by default) |
Input mode | The mains input and bypass input share a power source or use different power sources. |
Overvoltage category | OVC II |
Battery voltage (lead-acid battery) | 12 V battery: 30–44 batteries. 34 batteries: battery inverter output power is derated to 90%; 32 or 30 batteries: battery inverter output power is derated to 80%. |
2 V battery: 180–264 batteries. 204–214 batteries: battery inverter output power is derated to 90%; 180–204 batteries: battery inverter output power is derated to 80%. | |
The number of batteries in the positive battery string must be the same as that of batteries in the negative battery string. | |
NOTE: | |
The default number of batteries is 0. Set this parameter based on site requirements. | |
When the UPS works in normal mode, if the actual load rate exceeds the threshold that could trigger battery derating, an output overload alarm is generated. | |
Battery management | Intelligent battery management |
One-button cold start | In the case of a mains failure, batteries can start the UPS to power loads. |
Charger output power | Under rated conditions, the maximum charge power of a module is 5 kW. |
Charger current limit | Maximum 10 A for a module |
Battery string sharing | Battery string sharing is supported in a parallel system. No battery string is shared by default. |
Charging voltage (lead-acid battery) | Equalized charge voltage: 2.3–2.4 V/cell, default: 2.35 V/cell (30–42 batteries) |
Equalized charge voltage: 2.3–2.4 V/cell, default: 2.35 V/cell (44 batteries) | |
Float charge voltage: 2.23–2.3 V/cell, default: 2.25 V/cell (30–44 batteries) | |
Redundancy design | The auxiliary power supplies, centralized controllers, and parallel signals use redundancy design. |
No-load loss | 200K: 2 kW |
300K: 2.5 kW | |
ECO in a parallel system | Supported |
Power distribution system | TN-C, TN-S, TN-CS, TT |
As a global leading professional Huawei network hardware and solution provider, we have delivered Huawei, ZTE, Nokia, CISCO, Fiberhome, etc, equipment to 500+ customer groups in 90+ countries over the past 10 years. Know more
Strict 3-Level Quality Control procedure: 1st-Level inspection; 2nd-Level In-stock test; 3rd-Level 24-hour pre-delivery test to guarantee premium quality. Know more
What we offer to our customers is value rather than price. We enable customers to enjoy the benefit of our reliable delivery products and generate more value to the greatest extent. Know more
We provide customers with personalized and professional tech support by remote diagnosis, fault-location and troubleshooting. "We are here to help you instantly when you need it."
We continuously offer flexible payment methods such as Wire Transfer, Paypal, L/C, Western Union and Alipay, to help customer enjoy a more convenient shopping experience. Know more
We provide extensive document resources to guide our customers to targetly solve the problem they may meet. Know more
Our products come with 1-year warranty. Customers can ask for a repair, replacement or refund for a major product failure. Know more
We won't stop to develop rapid and cost effective shipping options, providing the excellent experience to our global customers. Know more
We offer not only network products but also network proposal, mainstream and cost-effective solution to assist customers eliminate the concerns.
Reviews
There are no reviews yet.