FusionServer 1288H V5 is a next-generation 1U, 2-socket rack server designed for Internet services, IDCs, cloud computing, enterprise IT, and telecom workloads.
Engineered for versatility, 1288H V5 delivers strong performance for core IT services, cloud platforms, high-performance computing, distributed storage, big data analytics, and other demanding applications.
This compact and reliable server offers low power consumption, high scalability, easy deployment, and simplified management — making it an ideal choice for modern, performance-driven data centers.
This article will introduce the Drive Configuration and the Internal Cabling of 1288H V5.
Drive Configuration
| Configuration | Maximum Front Hard Disks | Drive Management Mode |
| 4 x 3.5″ drive configuration | Front drive: 4 x 3.5″ Slots 0 to 3 support only SAS/SATA drives. |
1 x RAID controller card/PCHa Screw-in RAID controller card: installed in the RAID controller card connector on the mainboard. PCIe RAID controller card: must be installed in slot 1. |
| 8 x 2.5″ drive configuration | Front drive: 8 x 2.5″ Slots 0 to 7 support only SAS/SATA drives. |
1 x RAID controller card/PCHa
Screw-in RAID controller card: installed in the RAID controller card connector on the mainboard. |
| 10 x 2.5″ drive configuration 1 | Front drive: 10 x 2.5″ Slots 0 and 1 support only SAS/SATA drives. Slots 2 and 3 support SAS/SATA/NVMe drives. Slots 4 to 9 support only NVMe drives. |
1 x RAID controller card/PCHa
Screw-in RAID controller card: installed in the RAID controller card connector on the mainboard. |
| 10 x 2.5″ drive configuration 2 | Front drive: 10 x 2.5″ Slots 0 to 9 support only SAS/SATA drives. |
1 x RAID controller cardb
PCIe RAID controller card: must be installed in slot 1. |
| 10 x 2.5″ drive configuration 3 | Front drive: 10 x 2.5 Slots 0 to 5 support only SAS/SATA drives. Slots 6 and 7 support SAS/SATA/NVMe drives. Slots 8 and 9 support only NVMe drives. |
1 x RAID controller card/PCHa
Screw-in RAID controller card: installed in the RAID controller card connector on the mainboard. |
Note:
a: A RAID controller card or PCH can be used to manage common drives. The PCH supports only SATA drives.
b: The drives can be managed only by the Avago SAS3516 RAID controller card.
Internal Cabling
1288H V5 with difference Drive Chassis has different Internal Cabling, here we take an example for Server with 8 x 2.5″ Drives.
1,Indicator Board and VGA Board Cabling

| No. | P/N Code | Description |
| 1 | 04051947 | Low-speed signal cable for connecting a USB device to the mainboard (J173) |
| 2 | 04051924 | Low-speed signal cable for connecting the VGA board to the mainboard (J160) |
| 3 | 04051949 | Low-speed signal cable for connecting the indicator board to the mainboard (J167) |
2,DVD drive cabling

| No. | P/N Code | Description |
| 1 | 04050689 | High-speed cable for connecting the DVD drive to the mainboard (J67) |
| 2 | Power cable for connecting the DVD drive to the front-drive backplane (J11) |
3,SAS High-speed Cabling (Server with a Screw-in RAID Controller Card)

| No. | P/N Code | Description |
| 1 | 04051021 | SAS high-speed cable for connecting PORT A (J28) of the drive backplane to PORT A of the RAID controller card |
| 2 | 04051021 | SAS high-speed cable for connecting PORT B (J29) of the drive backplane to PORT B of the RAID controller card |
4, SAS High-speed Cabling (a PCIe RAID Controller Card in PCIe Riser Module 1)

| No. | P/N Code | Description |
| 1 | 04051021 | SAS high-speed cable for connecting PORT A (J28) of the drive backplane to C0 of the PCIe RAID controller card |
| 2 | 04051021 | SAS high-speed cable for connecting PORT B (J29) of the drive backplane to C1 of the PCIe RAID controller card |
5, SAS High-speed Cabling (a PCIe RAID Controller Card in PCIe Riser Module 2)

| No. | P/N Code | Description |
| 1 | 04051021 | SAS high-speed cable for connecting PORT A (J28) of the drive backplane to CN0 of the PCIe RAID controller card |
| 2 | 04051021 | SAS high-speed cable for connecting PORT B (J29) of the drive backplane to CN1 of the PCIe RAID controller card |
6, SAS High-speed Cabling (PCH Pass-through)

| No. | P/N Code | Description |
| 1 | 04051939 | SAS high-speed cable for connecting PORT A (J28) of the drive backplane to Mini SAS HD connector A (MINIHD PORT A/J86) |
| 2 | 04051939 | SAS high-speed cable for connecting PORT B (J29) of the drive backplane to Mini SAS HD connector B (MINIHD PORT B/J84) |
7, Drive Backplane Power and Low-speed Signal Cabling

| No. | P/N Code | Description |
| 1 | 04051990 | Power cable for connecting the drive backplane (J24) to the mainboard (J128) |
| 2 | 04051937 | Low-speed signal cable for connecting the drive backplane (J1) to the mainboard (J162) |
For other internal cabling of Server with 4 x 3.5″ Drives or 10 x 3.5″ Drives, you can contact supports@thunder-link.com. Or any needs for Xfusion Servers, please do not hesitate sales@thunder-link.com.