OLT

What is the command lines that we can use on the OLT to detect PRTE board status

Issue Description

Q:
MA5600T(  MA5600V800R005C32B138)  has 2 PRTE one of them is

damaged so how can we check it from command line

Alarm Information

ALARM 2849 FAULT MAJOR 0x15411026 ENVIRONMENTAL

2010-08-12 10:04:24 DST
ALARM NAME  : Fan power fault alarm
PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  0    EMU Type:  FAN
Name:  Power fault
Name:  Power fault
DESCRIPTION : Fan power fault alarm
CAUSE       : Power  fault
ADVICE      : Check power

Handling Process

A:
About the querying about the power board through command line please check below

commands :
If the two board boards is normal:
MA5600T(config)#interface emu 0
MA5600T(config-if-fan-0)#display fan
{ alarm<K>|environment<K>|system<K> }:alarm
Command:
display fan alarm
EMU ID: 0
—————————————————————————-
Alarm name                    Alarm state
—————————————————————————-
Read temperature fault       Normal
Fan block                            Normal
Temperature high              Normal
Power fault                         Normal
—————————————————————————-
If one of the power board is failure or does not exists
MA5600T(config-if-fan-0)#display fan alarm

EMU ID: 0
—————————————————————————-
Alarm name                    Alarm state
—————————————————————————-
Read temperature fault       Normal
Fan block                             Normal
Temperature high               Normal
Power fault                          Alarm
—————————————————————————-

Root Cause

null

Suggestions

Null

OLT

OLT

Categories:

Tags:

Comments are closed